200kV ~ 400kV Range
LQHVF 300kV/500pF Dual-Function Capacitor: Standards-Compliant Precision Solution
Certified Instrument for Power Equipment Testing
The LQHVF 300kV/500pF meets stringent international and Chinese standards including IEC 358, GB50150, and DL/T specifications. Engineered for power equipment commissioning and maintenance, this dual-function solution provides:
Full compliance with hand-over test requirements (GB50150-2006)
Precision measurement for resonance testing (DL/T 849.6-2004)
Preventive test capability per DL/T596-1996
Dual functionality as voltage divider and coupling capacitor
Industry-Leading Stability
Temperature coefficient of 5×10⁻⁵ %/°C ensures consistent performance across environmental variations per IEC 358 requirements.
Technical Specifications
Parameter | Specification | Standard Compliance |
---|---|---|
Rated Voltage | 300kV | IEC 358 Clause 4.1 |
Nominal Capacitance | 500pF | DL/T 849.6-2004 |
Voltage Ratio | 1000:1 | GB50150-2006 Annex B |
Accuracy | ≤±1% | Class 0.5 per IEC 60060-2 |
Dielectric Loss | <0.2% @20°C | DL/T596-1996 Clause 9 |
Partial Discharge | <10pC @300kV | IEC 60270 |
Operating Time | 60 minutes @300kV | GB50150-2006 Clause 7.3 |
Insulation Levels
HV Arm
330kV/1min
110% rated voltage
LV Arm
3kV/1min
IEC 358 Clause 5.3
Compliance with Industry Standards
GB50150-2006
Hand-over Test of Electric Equipment Installation Engineering
Sec 10.3: HV test requirements
Annex B: Measurement accuracy
Clause 7.3: Test duration
DL/T 849.6-2004
High-voltage Resonance Test Unit Specifications
Sec 5.2: Capacitance requirements
Annex A: Partial discharge limits
Clause 6.3: Temperature stability
DL/T596-1996
Preventive Test Code for Electric Power Equipment
Clause 9: Dielectric loss requirements
Sec 11.4: Insulation test procedures
Annex C: Test equipment specifications
IEC 358 (1990)
Coupling Capacitors and Capacitor Dividers
Clause 4.1: Rated voltage
Sec 5.3: Insulation levels
Clause 8.2: Temperature coefficient
Dual-Function Operation
As Precision Voltage Divider
Compliant with GB50150 hand-over test requirements for:
Transformer commissioning tests
Cable withstand voltage verification
GIS insulation integrity testing
As Coupling Capacitor
IEC 358-compliant signal coupling for:
Protection relay communication
Power line carrier (PLC) systems
SCADA data transmission
Design Features for Standardized Testing
Oil-Immersed Construction
Meets IEC 358 Clause 6.1 for dielectric fluid insulation and thermal stability.
Removable Component System
DL/T596-compliant design for field maintenance and calibration.
Dual Insulation System
Separate HV (330kV) and LV (3kV) insulation meets GB50150 Annex B requirements.
Testing Protocol Compliance
Preventive Maintenance Testing (DL/T596)
Measure capacitance and tanδ at 20°C
Perform 3kV/1min test on LV arm
Verify PD level
<10pc 80="" at="">Record temperature coefficient validation
Commissioning Tests (GB50150)
330kV/1min withstand test on HV arm
Accuracy verification at multiple voltage points
60-minute continuous operation test
Dielectric loss measurement at 20°C
Operational Benefits
Regulatory Compliance: Meets all Chinese and international testing standards
Certification Ready: Includes standard-compliant test reports
Thermal Stability: 5×10⁻⁵ %/°C coefficient ensures consistent results
Dual-Function Efficiency: Single instrument for measurement and communication
"The comprehensive standards compliance eliminated certification delays - we passed GB50150 hand-over tests 30% faster than with conventional equipment."
- Chief Engineer, Power Grid Construction Project
Installation & Certification Protocol
Documentation Review: Verify standard-compliant test certificates
Site Assembly: Install removable components per DL/T849.6
Insulation Verification:
HV arm: 330kV/1min test per GB50150
LV arm: 3kV/1min test per IEC 358
Performance Validation:
Dielectric loss measurement at 20°C
Accuracy verification at 50%, 80%, 100% Un
PD test at 300kV and 240kV
Continuous Operation Test: 60-minute run at 300kV
Certification: Issue GB50150-compliant hand-over report
Certification & Documentation
Each unit includes standard-compliant test reports:
GB50150-2006 Annex B test certificate
IEC 358 Clause 8 compliance report
DL/T596-1996 preventive test record
Temperature coefficient validation data
Third-party certified by CEPRI (China Electric Power Research Institute).