High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

200kV ~ 400kV Range

300kV/2000pF Precision Voltage Divider | 3500:1 Ratio & Extended Duty Operation

300kV/2000pF capacitive voltage divider with 3500:1 ratio and extended operation capability. Features ≤1% accuracy, <0.2% dielectric loss, and 330kV insulation withstand for precision high-voltage applications.


  • US$ 7,010.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 300kV/2000pF Capacitive Voltage Divider: Extended-Duty Precision Instrument

High-Resolution Measurement for Demanding Applications

The LQHVF 300kV/2000pF sets new standards in high-voltage precision with its exceptional 3500:1 ratio and extended-duty operation capability. Engineered for critical power system testing and calibration laboratories, this solution delivers:

  • Ultra-high 3500:1 ratio for 85.7V equivalent at 300kV

  • Continuous operation at 225kV (75% rated voltage)

  • Ultra-low dielectric loss (

    <0.2%) 20="" at="">
  • 330kV insulation withstand (110% rated voltage)

Extended Duty Operation

Unlimited operation at 225kV combined with 1-hour rating at 300kV provides unmatched flexibility for long-duration tests.

Technical Specifications

ParameterSpecificationPerformance Advantage
Rated Voltage300kVUltra-high voltage system testing
Rated Capacitance2000pFOptimal for precision measurements
Low Voltage Ratio3500:1Highest resolution in class
Accuracy≤±1%Exceeds IEC 60060-2 Class 0.5
Dielectric Loss<0.2% @20°CIndustry-leading insulation quality
Insulation Level330kV/60s110% rated voltage withstand
Cooling SystemONANPassive thermal management

100%

300kV operation

60 minutes maximum

75%

225kV operation

Continuous duty

50Hz

300Hz

Precision Design Features

Ultra-Low Loss Capacitors

Special dielectric formulation achieves<0.2% 20="" loss="" at="">

Removable Corona Rings

Aerospace-grade aluminum alloy rings prevent discharge at 300kV+.

Stabilized Removable Base

Engineered pedestal with seismic restraints and vibration damping.

Scalable HV Connection

Corona-free connectors for single (300kV) or series (600kV) configurations.

Extended Duty Performance

Continuous Operation Capability

Maintains ≤±1% accuracy during unlimited operation at 225kV (75% rated voltage) - ideal for long-duration tests like:

  • 72-hour transformer temperature rise tests

  • Extended cable aging studies

  • Continuous power quality monitoring

High-Resolution Measurement

3500:1 ratio delivers 85.7V equivalent at 300kV - enabling detection of micro-discharges and nanosecond transients.

Industry Applications

Calibration Laboratories

Reference standard for calibrating 300kV+ measurement systems with NIST-traceable accuracy.

Transformer Manufacturing

Extended induced voltage tests on 500kV transformers with continuous monitoring.

Research Facilities

Long-duration dielectric studies and material aging research at controlled voltages.

Operational Advantages

  • Unmatched Resolution: 3500:1 ratio enables new measurement capabilities

  • Extended Operation: Unlimited runtime at 225kV reduces test interruptions

  • Thermal Stability: ≤0.05% ratio drift during voltage transitions

  • Frequency Flexibility: Consistent accuracy from 50-300Hz

"The continuous operation at 225kV allowed us to complete 72-hour transformer tests without interruption - eliminating measurement gaps that previously affected our data accuracy."
               - Chief Engineer, Power Transformer Facility

Installation & Operation Protocol

  1. Site Preparation: Level surface with 6m clearance

  2. Assembly: Secure corona rings using alignment markers

  3. Grounding: Dual 35mm² cables to independent ground

  4. Configuration:

    • Select single-stage (300kV) or series (600kV)

    • Connect via special lead-wire to VF source

  5. Voltage Selection:

    • 300kV: Max 60 minutes continuous

    • 225kV: Unlimited operation

  6. Safety: Maintain 7m clearance during 330kV tests

Compliance & Standards

Certified to highest precision standards:

  • IEC 60060-1/2: High-voltage test techniques

  • IEEE 4: Standard for HV testing

  • ISO/IEC 17025: Testing laboratory competence

  • ASTM D150: Standard test methods for AC loss

Includes NIST-traceable calibration certificate.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message