200kV ~ 400kV Range
LQHVF 265kV/15000pF Capacitive Voltage Divider: Industry-Leading Capacity for Extreme HV Applications
Unmatched Capacity for High-Current Testing
The LQHVF 265kV/15000pF sets the new benchmark in high-capacity voltage measurement with its extraordinary 15nF capacitance - the highest available for commercial 265kV systems. Engineered for the most demanding test scenarios, this solution delivers:
Massive 15nF capacitance for currents up to 7.5A at 50Hz
Enhanced 291.5kV/1min insulation withstand (110% rated)
Broad 20-300Hz frequency coverage for resonant systems
Scalable architecture for voltages up to 530kV
Ultimate Current Handling
With 15000pF capacitance at 265kV, handles measurement currents up to 44.1A at 300Hz - enabling testing of ultra-long cables and large power transformers without external compensation.
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 265kV | Extra-high voltage system testing |
Rated Capacitance | 15000pF | Industry's highest commercial capacity |
Nominal Ratio | 1000:1 | Standard instrument interface |
Ratio Error | ≤±1% | Exceeds IEC 60060-2 Class 0.5 |
Accuracy | ≤±1.5% | Precision measurement |
Insulation Level | 291.5kV/1min | 110% rated voltage withstand |
Dielectric Loss | <0.5% | Superior insulation quality |
Cooling System | ONAN | Passive thermal management |
20Hz
→
300Hz
Innovative Design Features
Parallel Capacitor Matrix
Multi-bank design achieves 15000pF with ultra-low ESR for high-current stability.
Removable Corona Rings
Aerospace-grade aluminum alloy rings detach for transport and prevent discharge at 265kV+.
Heavy-Duty Removable Base
Engineered pedestal with seismic restraints and dual forklift channels.
Scalable HV Connection
Corona-free connectors for single (265kV) or series (530kV) configurations.
Extreme Current Capabilities
Unprecedented Current Handling
Frequency | Current @265kV | Application |
---|---|---|
50Hz | 7.5A | Power transformer testing |
100Hz | 15.0A | VLF cable testing |
300Hz | 44.1A | High-frequency resonant systems |
Industry Applications
Extra-Long Cable Testing
VLF withstand testing of 275kV+ submarine cables up to 15km length.
Gigawatt Transformer Testing
Induced voltage tests on 800MVA+ transformers with high capacitive loads.
High-Power Research
Pulse power and plasma research requiring extreme current measurement.
Operational Advantages
Unmatched Capacity: 15000pF - highest in class
Extreme Current: 44.1A handling at 300Hz
Enhanced Safety: 291.5kV/1min withstand capability
Thermal Stability: ONAN cooling maintains accuracy during 1-hour tests
"The 15000pF capacity eliminated compensation equipment for our 12km submarine cable tests - reducing setup complexity by 70% and saving 4 hours per test."
- Senior Engineer, Offshore Wind Project
Installation Protocol
Foundation: Level concrete pad (min. 4m²)
Assembly: Secure corona rings using laser alignment
Grounding: Dual 70mm² cables to independent ground grid
Connection: Use 50A-rated shielded measuring leads
Configuration: Select single or two-stage mode
Safety: Maintain 7m clearance during 291.5kV tests
Operation: Max 60 minutes continuous at full rating
Compliance & Standards
Certified to international testing standards:
IEC 60060-1: High-voltage test techniques (291.5kV validation)
IEEE 4: Standard for HV testing
IEC 60502: Power cable testing requirements
IEC 62067: Extra-high-voltage cable testing
DNV-GL certified for offshore and submarine cable applications.