200kV ~ 400kV Range
LQHVF 260kV/10000pF Capacitor Voltage Divider: High-Current Solution for Wide-Frequency Testing
Engineered for Demanding High-Current Applications
The LQHVF 260kV/10000pF voltage divider delivers exceptional performance in high-current measurement scenarios with its industry-leading 10nF capacitance. Designed for resonant test systems and power equipment validation, this solution provides:
Massive 10nF capacitance for high-current measurements up to 5A
286kV/1min insulation withstand (110% rated voltage)
Broad 20-300Hz frequency coverage for VLF to power frequency testing
Scalable architecture for voltages up to 520kV
High-Current Capability
With 10000pF capacitance at 260kV, handles measurement currents up to 4.9A at 50Hz - ideal for testing high-capacitance loads like long cables and large transformers.
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 260kV | EHV system testing capability |
Rated Capacitance | 10000pF | Highest commercial capacity for 260kV class |
Nominal Ratio | 1000:1 | Standard interface for instruments |
Ratio Error | ≤±1% | Exceeds IEC 60060-2 Class 0.5 |
Accuracy | ≤±1.5% | Laboratory-grade measurement |
Insulation Level | 286kV/1min | 110% rated voltage withstand |
Dielectric Loss | <0.5% | Minimal signal distortion |
Cooling System | ONAN | Passive thermal management |
20Hz
→
300Hz
Innovative Design Features
High-Current Capacitor Array
Parallel capacitor design achieves 10000pF with ultra-low inductance for accurate high-current measurement.
Removable Corona Rings
Aerospace-grade aluminum alloy rings prevent discharge and detach for compact transport.
Stabilized Removable Base
Heavy-duty pedestal with seismic restraints and forklift channels.
Scalable HV Connection
Corona-free connectors for single-stage (260kV) or series (520kV) configurations.
High-Current Capabilities
Maximum Current Handling
Calculated current capabilities at 260kV:
Frequency | Current | Application |
---|---|---|
50Hz | 4.9A | Power frequency testing |
100Hz | 9.8A | VLF cable testing |
300Hz | 29.4A | Resonant test systems |
Industry Applications
Long Cable Testing
VLF withstand testing of 220kV+ cables up to 5km length with high capacitance loads.
Large Transformer Testing
Induced voltage tests on 500MVA+ transformers with high magnetizing currents.
Resonant Test Systems
Frequency-tuned testing of high-capacitance equipment at 20-300Hz.
Operational Advantages
High-Current Tolerance: 29.4A capability at 300Hz
Thermal Stability: ONAN cooling maintains ≤0.2% drift during 1-hour tests
Wide Frequency Range: Consistent accuracy from 20Hz to 300Hz
Enhanced Safety: 286kV/1min insulation withstand
"The 10000pF capacity allowed us to test 4km 220kV cables without external compensation - reducing setup time from 3 hours to 30 minutes."
- Cable Testing Manager, Utility Company
Installation & Safety Protocol
Site Preparation: Level surface with 5m clearance radius
Assembly: Secure corona rings using alignment markers
Grounding: Dual 50mm² cables to station ground grid
Connection: Use high-current rated measuring leads
Configuration: Select single or two-stage mode
Safety: Maintain 6m clearance during 286kV tests
Duration: Maximum 60 minutes continuous operation
Compliance & Standards
Certified to international testing standards:
IEC 60060-1/2: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60502: Power cable testing requirements
IEC 60076: Power transformer testing
Third-party certified for 10000pF capacitance at 260kV.