200kV ~ 400kV Range
LQHVF 250kV/1000pF Capacitive Voltage Divider: Ultra-Compact Precision for Field Testing
Portable High-Voltage Measurement Solution
The LQHVF 250kV/1000pF redefines field-deployable high-voltage measurement with its unprecedented compact design and laboratory-grade accuracy. Engineered for testing teams requiring mobility without compromise, this solution delivers:
Industry-leading partial discharge: <2pC @250kV
Full 250kV rating in a 0.8×0.8m footprint
Lightweight 80kg construction for rapid deployment
Scalable configuration for voltages up to 500kV
Revolutionary Portability
At 60% smaller and 40% lighter than conventional 250kV dividers, it fits through standard doorways and deploys in 15 minutes.
Technical Specifications
Parameter | Specification | Field Advantage |
---|---|---|
Rated Voltage | 250kV | Transmission-level testing capability |
Accuracy | ≤ ±1% | Laboratory precision in field conditions |
Partial Discharge | <2pC @250kV | Ultra-clean measurements in noisy environments |
Dimensions | 800×800×2700mm (L×W×H) | Fits through standard access doors |
Weight | 80kg | Two-person portable deployment |
Operating Time | 60 minutes continuous | Extended test sequences |
Length
800mm
Width
800mm
Height
2700mm
Weight
80kg
Innovative Compact Design
Removable Aluminum Corona Rings
Aerospace-grade alloy rings detach for transport and reassemble in<5 minutes="" without="" tools.="">
Stabilized Removable Base
Low-center-of-gravity design with anti-tip features for confined spaces.
Corona-Free HV Connection
Scalable connectors enable single-stage (250kV) or series (500kV) configurations.
Vertical Space Optimization
2.7m height maintains required clearances while minimizing footprint.
Field Deployment Advantages
Rapid Setup Protocol
Position base (90 seconds)
Install main column (120 seconds)
Attach corona rings (180 seconds)
Connect measurement leads (60 seconds)
Total deployment time:<8 minutes="" with="" trained="" team.="">
Transport & Handling
Fits standard service elevator (1×1m cabin)
Components pack in 1.2m crates
No special lifting equipment required
Application Scenarios
Confined Space Testing
Ideal for indoor substations, tunnel cable installations, and offshore platforms where space is limited.
Mobile Test Laboratories
Enables 250kV testing capability in vehicle-mounted systems and containerized labs.
Operational Excellence
Ultra-Low PD:
<2pc enables="" sensitive="" measurements="" in="" emi="" environments="">Thermal Stability: Maintains ≤1% accuracy during 60-minute tests
Safety Integration: Built-in discharge rod holders
Variable Frequency: Compatible with 10-300Hz power sources
"The compact design allowed us to perform 220kV tests in a switchgear room where conventional dividers couldn't fit - reducing outage time by 65%."
- Field Testing Manager, Utility Company
Safety & Operation Protocol
Site Survey: Verify 3m overhead clearance
Assembly: Secure all corona ring connections
Grounding: Connect dual 25mm² cables to station grid
Measurement: Use shielded leads to VF source
Configuration: Select single or two-stage mode
Clearance: Maintain 3m radius during operation
Decommissioning: 15-minute discharge before disassembly
Compliance & Standards
Certified to international electrical standards:
IEC 60060-1/2: High-voltage test techniques
IEC 60270: Partial discharge measurements
IEEE 4: Standard for HV testing
OSHA 1926.1400: Crane and derrick safety
Third-party verified at 250kV with<2pc pd="" certification.="">