200kV ~ 400kV Range
LQHVF 230kV/3000pF Capacitive Voltage Divider: Precision High-Voltage Measurement
Advanced HV Measurement for Critical Infrastructure
The LQHVF 230kV/3000pF Capacitive Voltage Divider delivers laboratory-grade accuracy in field environments. Designed for high-voltage systems up to 253kV (110% rated voltage), this single-phase solution enables:
Precision ratio measurements with ≤1% voltage error
Dielectric loss analysis (
<0.5% tan="">Frequency response testing (20-300Hz range)
Corona-free operation at maximum voltage
Certified Performance
Exceeds IEC 60060-2 standards with 110% rated voltage withstand for 60 seconds and NAN (Natural Air Natural) cooling for thermal stability during continuous 1-hour operations.
Technical Specifications
Parameter | Specification | Industry Benefit |
---|---|---|
Rated Voltage | 230kV | Transmission-level measurement capability |
Accuracy | ≤ ±1.5% | Meets IEEE 4 precision requirements |
Voltage Ratio | 1000:1 nominal | Standard interface for test instruments |
Dielectric Loss | <0.5% | Superior insulation integrity monitoring |
Cooling System | NAN (Natural Air Natural) | Maintains thermal stability during 1-hour operations |
Frequency Range | 20-300Hz | Covers power frequency and harmonic analysis |
Engineering Innovations
Corona-Free HV Interface
Aluminum alloy corona rings prevent partial discharge at 230kV+, with scalable connections for multi-stage configurations.
Modular Transport System
Removable pedestal and compact corona rings enable secure shipping and rapid onsite assembly.
Dual-Measurement Capability
Special lead-wire interface measures both single-stage and serial connection voltages via VF power sources.
Industry Applications
Substation Commissioning
Verifies switchgear insulation at 253kV per IEC 62271-200 with certified 1000:1 ratio.
Transformer Diagnostics
Measures dielectric loss tangent during maintenance with 300Hz frequency resolution.
Cable & GIS Testing
Performs withstand voltage tests on 230kV cables with corona-free connections.
Operational Safety Features
Stabilized Base: Anti-tip design with removable pedestal
Dual Grounding: Ensures equipotential bonding during tests
Visual Corona Indicators: Aluminum rings show discharge inception
Voltage Scalability: Adapts to single or two-stage configurations
"The 1000:1 ratio with ±1.5% accuracy eliminates calibration uncertainties in critical HV tests - essential for compliance certification."
- Senior Engineer, Global Power Testing Lab
Operational Protocol
Pre-Test: Verify all corona ring connections
Connection: Use shielded measuring leads to VF source
Duration: Maximum 60 minutes continuous operation
Safety: Maintain 5m clearance during 253kV tests
Post-Use: Execute 15-minute discharge cycle
Compliance & Standards
Designed to meet global electrical testing standards:
IEC 60060-1/2: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
OSHA 1910.269: Electrical safety requirements