Relay Tester/Secondary Circuit Tester
LQMG2000B Double Clamp Digital Phase Meter
Handheld Electrical Phase Analysis Solution
The LQMG2000B combines high-voltage measurement capabilities (500V AC) with non-contact current clamps for comprehensive phase analysis in power systems. Ideal for transformer testing, meter verification, and differential protection checks without circuit disconnection.
Product parametersProduct Parameters
Reference to working conditions
| Influence quantity | Benchmark conditions | Working conditions |
| Ambient temperature | 23℃±1℃ | <80% |
| Ambient humidity | 40%~60% | 10℃~40℃ |
| Signal waveform | Sine wave β= zero point zero five | Sine wave β= zero point zero five |
| Signal frequency | 50Hz±1Hz | 45Hz~65Hz |
| Instrument operating voltage | 9V±0.1V | 9V±1V |
| Voltage amplitude during phase measurement | 100V±20V | 30V~500V |
| Current amplitude during phase measurement | 1A±0.2A | 10mA~20.00A |
| External electric and magnetic fields | Avoid | |
| Location of the tested wire | The measured wire is at the approximate Centroid of the jaw | |
General specifications
| Function | Direct testing of phase, AC current, AC voltage, AC leakage current, and phase sequence; Transformer group, inductive and capacitive circuit discrimination; Power factor and power indirect testing |
| Power supply | DC9V alkaline Dry cell (1.5V LR6 × 6) |
| Working current | Turn on the backlight, with a maximum of 35mA and the battery working continuously for about 15 hours |
| Turn off the backlight, the instrument consumes approximately 5mA of power, and the battery operates continuously for approximately 100 hours | |
| Display mode | LCD display, white screen backlight function, suitable for dim places |
| LCD Size | 70mm×62mm ;Display Domain:64mm×54mm |
| Instrument size | Length, width, and thickness: 196mm × 92mm × 54mm |
| Sample Rate | About 3 times/second |
| Range | AC voltage: 0-20V/200V/500V |
| AC current: 0-200mA/2A/20A | |
| Phase: 0-360 ° | |
| The amplitude range of the measured signal during phase measurement | When measuring U1-U2 phase: 30V~500V |
| When measuring I1-I2 phase: 10mA~10.00A | |
| When measuring U1-I2 or I1-U2 phase: 10V~500V, 10mA~10.00A | |
| Data hold | During the test, press the HOLD key to maintain the data, and the "DH" symbol is displayed |
| Automatic shutdown | After about 15 minutes of startup, the instrument automatically shuts down to reduce battery consumption |
| Voltage detection | When the battery voltage is below 7.8V-8V, replace the battery |
| Instrument quality | The host is approximately 1140g (with battery), and the watch clamp is approximately 170g × 2. Test line approximately 250g |
| Test line length | 1.5m |
| Current clamp wire length | 2m |
| Operation temperature | -10 ℃~40 ℃; Below 80% Rh |
| Storage temperature and humidity | -10 ℃~60 ℃; Below 70% Rh |
| Impedance | The input impedance of each test voltage range is: 1m Ω |
| When measuring the phase of U1U2, the voltage input impedance is 40k Ω | |
| Pressurization | Withstand a sine wave AC voltage of 1000V/50Hz between the instrument circuit and the casing for 1 minute; Test of withstanding a sine wave AC voltage of 500V/50Hz between two voltage input terminals for 1 minute |
| Insulation | ≥ 10m Ω between instrument circuit and casing, and between two voltage input terminals |
| Structure | Double insulation |
Basic error and performance indicators under benchmark conditions
| Voltage | 20V | 0.01V | ± (0.5% of range) ° |
| 200V | 0.1V | ||
| 500V | 1V | ||
| Current | 200mA | 0.1mA | ± (0.5% of range) ° |
| 2A | 1mA | ||
| 20A | 10mA | ||
| Phase | 0~360° | 1° | ±1° |
Key Specifications
Voltage Range: 0-500V AC (50/60Hz)
Current Clamps: 0.5-1000A AC (non-contact)
Phase Measurement: 0-360° (±1° accuracy)
Display: 25mm high-contrast LCD (70° adjustable)
Safety Rating: 1000V/50Hz insulation
Core Functionality
1. Comprehensive Phase Analysis
U-U, I-I, U-I phase angle measurement
Three-phase sequence identification
Transformer wiring group detection
2. Non-Contact Current Measurement
Dual insulated clamps (no circuit interruption)
Anti-short circuit design
Automatic current range detection
3. Enhanced Safety Features
500V input protection
10MΩ insulation resistance
Rubber shock-absorbing casing
User Advantages
Ergonomic Design
70° adjustable display for optimal viewing
Time Savings
No circuit disconnection required
Data Integrity
Isolated inputs prevent measurement errors
Safety Compliance
Withstands 1000V/50Hz between clamps and chassis
500V AC 1min withstand voltage test passed
IP54 rated enclosure
Why Professionals Choose LQMG2000B
Versatile - Measures all phase relationships (U-U, I-I, U-I)
Safe - Engineered insulation materials prevent accidents
Precise - ±1° phase measurement accuracy