Relay Tester/Secondary Circuit Tester
LQHV-702 Microcomputer Relay Protection Test Set
Advanced 3-Phase Relay Testing Solution
The LQHV-702 represents the latest generation of microcomputer-based relay protection test equipment, combining precision measurement with robust safety features for electrical maintenance professionals. Compliant with IEC 60255 standards, this tester delivers 4-phase voltage and 3-phase current outputs in a compact, portable design.
Key Technical Specifications
Voltage Output: 4×120V (phase-to-neutral)
Current Output: 3×40A continuous (120A for 10 seconds)
Display: 320×240 dot matrix LCD with Chinese/English interface
Accuracy: ±0.5% for voltage/current measurement
Protection: Built-in overcurrent/overvoltage protection with soft-start
Core Product Features
1. Multi-Functional Testing Capabilities
The LQHV-702 supports comprehensive relay testing including:
Differential protection testing
Auto-reclosing simulation
Transient fault reproduction
Harmonic analysis (up to 15th order)
2. Dual Operation Modes
Offers flexible testing options:
Standalone Operation: Rotary mouse control with intuitive menu navigation
PC-Connected Mode: Windows-based software for automated test sequences and report generation
3. Enhanced Safety Design
Intelligent heat dissipation system
Fault self-diagnosis with lockout protection
Isolated DC power outputs (110V/220V)
Product Parameters
Ac current output
Output precision | 0.2 class |
Phase current output (effective value) | 0~40A |
Triple current output (effective value) | 0~120A |
Long-term permissible operating value of phase current (effective value) | 10A |
Maximum output power of phase current | 450VA |
Output power at maximum output of three- phase parallel current | 900VA |
Three parallel current maximum output allowable operating time | 10s |
Frequency range (fundamental wave) | 0~ 1000Hz (online) 0~300Hz (stand-alone) |
Harmonic frequency | 0~ 20 times (online) 0~6 times (stand-alone) |
DC current output
Output precision | 0.5 class |
Output current | 0 ~ ±10A/ phase, 0 ~ ±30A/ terad |
Maximum output load voltage | 20V |
AC voltage output
Output precision | 0.2 class |
Phase voltage output (effective value) | 0~120V |
Line voltage output (effective value) | 0~240V |
Phase voltage/line voltage output power | 80VA/100VA |
Frequency range (fundamental wave) | 0~ 1000Hz (online) 0~300Hz (stand-alone) |
Harmonic frequency | 0~ 20 times (online) 0~6 times (stand-alone) |
DC voltage output
Output precision | 0.5 class |
Phase voltage output amplitude | 0~±160V |
Line voltage output amplitude | 0~±320V |
Phase voltage/line voltage output power | 70VA/140VA |
Switch quantity and time measurement
three-phase | note | |
Switching input | 8 road | empty contact: 1 ~ 20mA, 24V |
potential contact access:"0":0~ +6V; "1":+11 V~ +250V | ||
Switching output | 4 pair | DC:220V/0.2A;AC:220V/0.5A |
Time measurement | measurement range is 0.1ms ~ 9999s | measurement accuracy is 0.1ms |
Why Choose LQHV-702?
High-Capacity Output: 120A short-term current for demanding tests
Portable Design: 30% smaller than conventional test sets
Smart Connectivity: USB/RS232 interfaces for data transfer
Comprehensive Software: Includes waveform replay and vector analysis tools
Technical Support
Our engineering team provides:
On-site calibration guidance
IEC/ANSI test templates
24-month warranty coverage