Relay Tester/Secondary Circuit Tester
LQHV-103 CT/PT Comprehensive Test System
The LQHV-103 is an all-in-one field testing solution for current and voltage transformers (CT/PT), combining excitation characterization, ratio verification, and metrological compliance testing in a single portable unit.
Product Parameters
Function Table
| I. Current Transformer (CT) | II. Voltage Transformer (PT) |
| 1. Magnetization Curve | 1. Excitation Characteristic Test |
| 2. Transformation Ratio Test | 2. Transformation Ratio Test |
| 3. Polarity | 3. Polarity |
| 4. 5% and 10% error curve | 4. Withstand Test of Power Frequency |
| 5. Current Injecting | 5. Degauss |
| 6. Degauss | 6. Calculation of Knee Point Value |
| 7. Withstand Test of Power Frequency Alternating Current | |
| 8. Automatic Calculation of Excitation Knee Point Value |
Technical Parameter Table
| Major Technical Parameters | |
| Operational Power Supply | AC220V±20V, 50~60Hz |
| Equipment Power Supply Output Waveform | Sine Wave |
| Single Machine Output Voltage of Excitation Characteristic | 0~1200V |
| Excitation Output Current Set | 0~20A |
| Single Machine Output Current of Transformation Ratio Test | 0~600A |
| CT ratio measurement range | 5~25000A/5A(5000A/1A) |
| PT ratio measurement range | 1~500KV |
| Error | ≤0.5%(0.2%*Reading+0.3%*Range) |
| Operating Temperature | -10℃~+40℃ |
| Relative Humidity | <90RH% |
| Altitude | ≤1000m |
| Overall Dimension(Length*Width*Height) | 450*280*260(mm) |
| Weight | ≤30Kg |
Product Highlights
1. Intelligent Field Testing
Single-unit operation: No external devices required
Auto-diagnosis: Identifies saturation points (knee-point voltage)
Graphical interface: 7" LCD with touch-assisted controls
2. Advanced Data Management
3,000 test records with flash storage
USB export for Word/Excel reports
Built-in thermal printer for instant results
3. Rugged Portability
22kg lightweight design
IP52 protection rating
-10°C to 50°C operating range
Typical Applications
Substation Maintenance
Periodic verification of protection-class CTs
Metering Validation
Accuracy testing for revenue-grade PTs
Manufacturing QC
Production-line transformer testing
Testing Workflow
Connect test leads to transformer secondary
Select test mode (excitation/ratio/error curve)
Initiate automated test sequence
Review results on-screen or print directly
Save data to USB for further analysis
Technical Advantages
Dual-mode excitation: Tests both CTs and PTs without reconfiguration
Smart demagnetization: Prepares transformers for accurate testing
Safety features: Overcurrent/overvoltage protection circuits
Engineered for utility crews, testing laboratories, and industrial maintenance teams, the LQHV-103 delivers laboratory-grade accuracy in field conditions, significantly reducing transformer testing time while ensuring regulatory compliance.










