High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Relay Tester/Secondary Circuit Tester

LQHV-109A Smart CT/PT Analyzer | Automatic Transformer Tester with Error Curve Analysis

Professional LQHV-109A CT/PT analyzer performs automatic transformer testing with 5%/10% error curve generation. GB 20840 compliant for lab and field applications.


  • US$1.00; Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHV-109A Intelligent CT/PT Test System

Advanced transformer analysis with automatic error curves and field-ready portability (≤22kg)

Product Parameters

The main parameters

ItemParameters
Power supplyAC220V±10% 、50Hz
Equipment output0 ~ 2500Vrms, 5kVA (Max set value 20A)
High current output0~1000A
Excitation precision≤0.5%(0.2%* read +0.3%* range)
Secondary

winding resistance

measurement

Range0.1~300Ω
precision≤0.5%(0.2%* read +0.3%* range)
Secondary actual load

measurement

Range5~500VA
precision≤0.5%(0.2%* read+0.3%* range) ± 0.1VA
Phase measurement

(Angle difference)

precision4min
resolution0.1min
Ratio errorprecision0.05%
CT Turns Ratio

measurement

Range≤25000A/5A(5000A/1A)
precision≤0.5%
PT Turns Ratio

measurement

Range≤500kV
precision≤0.5%
Work conditionTemperature:-10℃ ~ 40℃,Humidity:≤90%,Altitude:≤1000m
size410mm × 260mm × 340mm
weight of the≤22kg

Comprehensive Testing Solutions

Dual Transformer Analysis

  • Complete CT & PT testing

  • No external equipment needed

Smart Error Analysis

  • Automatic 5%/10% error curves

  • Excitation inflection point detection

Field Efficiency

  • Built-in thermal printer

  • USB data export (Word reports)

Technical Specifications

FeatureSpecification
ControllerIntelligent touchscreen operation
DisplayLarge LCD with graphical interface
Data Storage3000+ test records (power-loss protection)
ConnectivityUSB for PC report generation
Weight≤22kg portable design

Certifications & Standards

  • GB 20840.2-2014 (Voltage Transformers)

  • GB 20840.3-2013 (Current Transformers)

  • IEC 61869-1

Simplified Workflow

  1. Connect to CT/PT terminals

  2. Select test parameters

  3. Initiate automatic analysis

  4. Review error curves/results

  5. Print or export reports

Industry Applications

Utility Substations

Protection relay verification

Metering Systems

Billing accuracy validation

Industrial Maintenance

Transformer condition assessment

Key Advantages

  • All-in-one testing: Complete CT/PT analysis in single unit

  • Time-saving automation: Automatic curve generation

  • Field-ready: Lightweight with instant reporting

  • Regulatory compliant: Meets latest GB standards

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message