LQHV-103A Intelligent CT/PT Field Test System

All-in-one solution for protection-class and metering transformer verification with automatic error curve generation and field reporting capabilities.

Product Parameters

Function Table

I. Current Transformer (CT)II. Voltage Transformer (PT)
1. Magnetization Curve1. Excitation Characteristic Test
2. Transformation Ratio Test2. Transformation Ratio Test
3. Polarity3. Polarity
4. 5% and 10% error curve,ALF4. Withstand Test of Power Frequency
5. Current Injecting5. Resistance Test
6. FAST TEST6. Calculation of Knee Point Value
7. Withstand Test of Power Frequency Alternating Current7. Actual Secondary Load Test
8. Automatic Calculation of Excitation Knee Point Value
9. Actual Secondary Load Test
10. Resistance Test

Technical Parameter Table

Major Technical Parameters
Operational Power SupplyAC220V±20V, 50~60Hz
Equipment Power Supply Output WaveformSine Wave
Single Machine Output Voltage of Excitation Characteristic0~1200V
Excitation Current Set0~20A
Single Machine Output Current of Transformation Ratio Test0~600A
CT ratio measurement range5~25000A/5A(5000A/1A)
PT ratio measurement range1~500KV
Load Range5~500VA
Resistance measurement range0.1~300Ω
Error≤0.5%(0.3%*Reading+0.2%*Range)
Operating Temperature-10℃~+40℃
Relative Humidity<90RH%
Altitude≤1000m
Overall Dimension(Length*Width*Height)450*350*350(mm)
Weight≤28Kg

Key Features

① Dual-Mode Testing

Simultaneous CT & PT analysis without reconfiguration

② Smart Curve Generation

Automatic 5%/10% error curves with knee-point detection

③ Field Reporting

Built-in thermal printer + USB export to Word/Excel

④ Regulatory Compliance

Meets GB 20840.2-2014, IEC 61869-1 standards

Workflow Efficiency

  1. One-Touch Setup: Automatic wire detection

  2. Parallel Testing: Run multiple test sequences simultaneously

  3. Data Management: Store 3000+ tests with power-loss protection

  4. Results Delivery: Print or export via USB 2.0

Technical Specifications

  • Display: 7" color LCD with touch interface

  • Printer: 58mm thermal, 30 lines/second

  • Storage: 8GB flash (expandable via USB)

  • Power: AC 220V±15% / 50Hz

  • Dimensions: 320×280×150mm

  • Weight: 21.5kg (field-portable)

Typical Applications

Substation Maintenance

Routine testing of protection CTs

Metering Validation

Accuracy verification for billing transformers

Manufacturing QC

Production line transformer testing

Standards Compliance

  • GB 20840.2-2014 (PT)

  • GB 20840.3-2013 (CT)

  • IEC 61869-1

  • DL/T 726-2013

>>>WhatsApp Communication<<<