High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Relay Tester/Secondary Circuit Tester

LQHV-602 Portable Waveform Recorder | Fault Recording & Generator Testing Device

The LQHV-602 portable waveform recorder combines fault recording, generator testing, and real-time power system analysis in one compact industrial-grade device with DSP precision.


  • US$1.00; Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHV-602 Portable Waveform Recorder: Multi-Function Power Analysis Solution

Industrial-Grade Portable Measurement Device

The LQHV-602 represents the next generation of portable waveform recorders, integrating fault recording, generator characteristic testing, and real-time power system analysis into a single compact unit. Designed for field engineers, this device combines laboratory-grade accuracy with rugged portability.

Product parametersProduct Parameters

Technical parameters

Hardware configuration
Display screen15.6 "LCD; resolution: 1366 × seven hundred and sixty-eight
StorageHard drive 120GB, memory 4GB
InterfaceNetwork: 1 10/100Mbps 802.3u interface, 2 USB interfaces
Number of channels
Analog quantity16 routes
Switching quantity16 routes
Derived quantity24 routes
Channel
Synchronous sampling frequency10k/s、20k/s、50k/s、100k/s optional
SafetyGalvanic isolation withstand voltage 3000VDC
Working power supply
AC power supplyRated voltage: single-phase 220V, 50Hz, allowable deviation -15%~+15%
DC power supplyRated voltage: 220V, allowable deviation -15% to+15%
Structure
Chassis size (mm)407 (width) × 150 (high) × 370 (deep)
Weight10kg (including aluminum alloy packaging box)
Environment
Operation temperatureIndoor use: -5~+45 ℃, relative humidity 5-95%
Storage environmentIndoor storage: -5~+45 ℃, humidity below 95rh% (non condensing)

Analog channel

Technical indicators
A/D resolution16 bit
Effective value accuracy0.2%
Channel Type
Ac signalCalculate effective value using RMS (root mean square) algorithm
Dc signalCalculate the effective value using the average algorithm
Speed signalProcess and extract zero crossing information, calculate parameters such as speed and power angle
4-20mA signalCalculate the effective value using the average algorithm
Measuring range
AC voltage channelAC150V~AC1000V
AC current channelDirect access: AC10A
Current clamp: AC1A~AC200A
DC voltage channelDC±100mV、DC±2000V
DC current channelDirect access: DC ± 200mA
Hall current clamp: DC ± 100A
Speed channelPhotoelectric sensors or eddy current sensors; 1: 1 or 1:60

Derived quantity

Types ofaccuracy
Frequency±0.02Hz
Active power0.5%, cos φ 1.0-0.5 Voltage > 50% Current > 10%
Reactive power0.5%, sin φ 1.0-0.5 Voltage > 50% Current > 10%
Difference between two vectors, sum of two vectors, AC impedance0.5%
Power factor/positive sequence/negative sequence/zero sequence/two-phase negative sequence/synchronous pressure difference1%
Phase angle difference, measured power angle, line power angle±0.3°
Calculate work angle±1.5°
Scalar sumDetermined by reference parameters
Scalar differenceDetermined by reference parameters
linear functionDetermined by reference parameters

Switching channel

Channel TypeTechnical Parameter
Combination of 8 active nodes and 8 passive nodesActive node access to DC24~220V
8 passive nodes, 4 active nodes, and 4 output channelsActive node access to DC24~220V
Output capacity empty node output, AC220V/5A
16 passive nodes/

Core Functionalities

1. Advanced Fault Recording

  • Continuous monitoring of equipment parameters

  • Pre-fault and post-fault data capture

  • Waveform analysis for root cause diagnosis

2. Generator Testing Suite

  • No-load characteristic tests

  • Short-circuit tests

  • Excitation system tests (step response, de-excitation)

  • Synchronization testing

3. Real-Time Power Analysis

  • Analog & digital input monitoring

  • Harmonic analysis up to 50th order

  • Sequence component calculation (positive/negative/zero)

Field Applications

Power Utilities

Substation equipment monitoring and fault analysis

Industrial Plants

Critical machinery protection and diagnostics

Generator Maintenance

Commissioning and periodic testing of generators

Operational Advantages

  1. Compact Design: 30% smaller than conventional recorders

  2. Flexible Configuration: Modular input channels (4-16 analog inputs)

  3. Intelligent Analysis: Automatic report generation

  4. Rugged Construction: IP54 rated for field use

Compliance & Standards

The LQHV-602 meets stringent industry requirements including:

  • IEC 61000-4-30 (Power quality measurement)

  • IEEE C37.111 (COMTRADE file format)

  • GB/T 14598.301 (Dynamic performance requirements)

With its combination of high-speed DSP processing, industrial-grade reliability, and comprehensive analysis capabilities, the LQHV-602 portable waveform recorder sets a new standard for field measurement devices in power systems and industrial applications.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message