Relay Tester/Secondary Circuit Tester
LQHV-1200 Protection Relay Test Set
Next-Generation 6-Phase Relay Testing Platform
The LQHV-1200 redefines protection relay testing with its 6-phase voltage/6-phase current output architecture and DSP+FPGA control system. Engineered for complex applications including transformer differential protection and plant auto-reclosing systems, this tester delivers laboratory-grade precision in field-ready packaging.
Core Technical Specifications
Output Channels: 6× voltage (0-120V) + 6× current (0-40A/phase, 120A short-term)
Control System: Dual DSP+FPGA with 16-bit DAC resolution
Waveform Accuracy: ±0.1% magnitude, ±0.2° phase angle
Communication: USB 3.0, Ethernet (IEC 61850-9-2 LE support)
Weight: 14.5kg (with carry handles)
Breakthrough Testing Capabilities
1. Multi-Phase Output Matrix
12-phase combined output modes (6V+6C)
Native support for 3-winding transformer differential tests
Programmable sequence output for auto-reclose simulations
2. Hybrid DSP+FPGA Architecture
DSP handles real-time signal processing (4μs update rate)
FPGA manages parallel output channels
16-bit DAC ensures 0.01% THD at full load
3. Linear Amplifier Technology
0.1Hz-5kHz frequency response
<1μV noise floor for sensitive relay testing
Active impedance matching (0.1Ω-10kΩ)
Workflow Optimization Features
Automated Test Sequences
Pre-loaded templates for 25+ common relay types
Real-Time Analytics
On-screen vector diagrams + phasor calculations
Portable Operation
Integrated carrying handles + shock-mounted components
Product Parameters
argument
Current channel number | Standard 6 phase |
Voltage channel number | Standard 6 phase |
Ac current output range | 30A/phase or 180A (six parallel) |
Dc current output range | 10ADC/phase |
Ac voltage output range | 120VAC/phase |
Dc voltage output range | 160VDC/phase |
Ac current output
6 phase current output per phase (effective value) | 0 ~ 30A output precision 0.2 |
3 phase current output per phase (effective value) | 0~60A |
6 phase parallel current output (RMS) | 0~180A |
Phase current long-term allowable working value (RMS) | 10A |
Maximum output power of phase current | 450VA |
T6 phase parallel current maximum output power) | 1000VA |
6 Allowable working time for maximum output of phase parallel current | 10s |
Frequency range (fundamental) | 0~1000Hz |
Harmonic frequency | 0 to 20 times |
Dc current output
Current output | 0 ~ ±10A/phase output accuracy 0.5 level |
Maximum output load voltage | 20V |
Ac voltage output
Phase voltage output (RMS) | 0 ~ 120V output precision 0.2 |
Line voltage output (RMS) | 0~240V |
Phase voltage/line voltage output work | 80VA / 100VA |
Frequency range (fundamental) | 0~1000Hz |
Harmonic frequency | 0 to 20 times |
Dc voltage output
Phase voltage output amplitude | 0 ~ ±160V output accuracy 0.5 |
Line voltage output amplitude | 0~±320V |
Phase voltage/line voltage output power | 70VA / 140VA |
Switching value
8 switch inputs | Null contact 1 ~ 20mA, 24V |
0Potential contact access "0" : 0 ~ +6V; 1: +11 V to +250 V | |
4 pairs of switching output | DC:220 V/0.2 A;AC:220 V/0.5 A |
Time measuring range
Time measuring range | 0.1ms ~ 9999s |
Measurement accuracy | 0<0.1mS |
Enhanced Safety Systems
Multi-stage thermal protection (70°C auto-throttling)
Isolated DC outputs (220V/5A, 110V/10A)
Galvanic separation between control/output circuits
Why Choose LQHV-1200?
Future-Proof Design - Field-upgradable via USB (FPGA firmware)
Time Savings - 6-phase simultaneous testing cuts project time by 60%
Investment Protection - 5-year extended warranty available