High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

HVDC Protection Resistor

HDVR-800kV/100mA Ultra-HVDC Protection Resistor | 100kΩ 800kV Safety System

800kV/100mA HVDC protection resistor with 100kΩ rating provides critical over-current/voltage protection for ultra-high voltage DC test systems up to 800kV.


  • US$1.00; Negotiated Price
  • Lead time: 60days

>>>WhatsApp Communication<<<

Product Details

Product Tags

HDVR-800kV/100mA Ultra-HVDC Protection Resistor

Product Overview

Designed for extreme voltage applications, the HDVR-800kV/100mA resistor provides essential protection for ultra-HVDC test systems operating at up to 800kV DC, featuring a 100kΩ current-limiting design with <5% annual drift.

Technical Specifications

Electrical Parameters
Rated Voltage800kV DC
Rated Current100mA continuous (150mA peak)
Resistance Value100kΩ ±3% (annual drift <5%)
Power Dissipation10kW continuous (15kW peak)
ConstructionPrecision nichrome wire on reinforced epoxy tube

Protection System Architecture

Dual-Resistor Network

  • AC Side Protection: 10kΩ transformer output resistor

  • DC Side Protection: 100kΩ main limiting resistor

  • Adjustable mounting with positive-lock mechanism

Failure Protection Mechanism

Unprotected System Risks

  1. Fault currents exceed 100A during short-circuit

  2. Rectifier stacks (D1-D4) destroyed in microseconds

  3. Transformer insulation failure occurs

  4. Cascading system damage

HDVR Protection Benefits

  1. Peak current limited to <120mA

  2. Voltage transients limited to <108%

  3. Fault energy contained to single module

  4. System components remain protected

Design Features

  • Voltage Grading: 7-stage capacitive grading system

  • Thermal Management: Oil-immersed cooling option

  • Mechanical: 3.2m epoxy-fiberglass core with corona shields

  • Monitoring: Integrated voltage divider taps

Protection Performance

Fault ConditionProtection EffectResponse Time
Load short-circuitCurrent <120mA<50μs
Capacitor failureLocalized damage only<300μs
Voltage spikesOvershoot <8%<80μs

Installation Requirements

  1. Minimum 5m clearance from grounded surfaces

  2. Vertical mounting required (max 5° deviation)

  3. Annual resistance verification (±5% tolerance)

  4. Pre-commissioning hi-pot test at 960kV

  5. Corona inspection at 500kV AC

Compliance Standards

  • IEC 62271-1 (Ultra-high voltage standards)

  • IEEE Std 1313.2 (Extreme voltage design)

  • EN 60060-1 (High-voltage test techniques)

  • ASTM D2304 (Epoxy material standards)

Typical Applications

  • Ultra-HVDC transmission research

  • Particle accelerator power systems

  • 800kV+ capacitor bank testing

  • High-energy physics experiments

  • Next-gen rectifier protection

The HDVR-800kV/100mA resistor is engineered for the most demanding ultra-high voltage applications, where conventional protection methods fail. Its 100kΩ value and 10kW power rating make it ideal for protecting systems testing capacitive loads up to 25nF at 800kV.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message