Charging Transformer
HCTT-250kV/0.5A Heavy-Duty Charging Transformer
Product Overview
The HCTT-250kV/0.5A sets new standards in high-power testing with 125kVA capacity and 0.5A output current, specifically engineered for long-duration industrial insulation tests and high-energy applications.
Technical Specifications
| Power Parameters | |
|---|---|
| Rated Capacity | 125kVA (±2%) |
| Input Voltage | 380V 3-phase ±5% (Exciting Winding) |
| Output Voltage | 250kV DC/AC (HV Winding) |
| Current Ratings | 328.9A (Input) / 0.5A (Output) |
| Frequency | 50Hz ±0.5% (60Hz optional) |
| Measurement Accuracy | ±0.2% via 1000:1 ratio winding |
Performance Characteristics
Core Performance
No-load Current: ≤8% of rated current
Waveform Distortion: ≤8% THD at full load
Over-voltage Withstand: 275kV (110%) for 60 seconds
Efficiency: 92% at 80% load
Robust Design Features
| Capability | Specification |
|---|---|
| Over-current | 150% (0.75A) for 5 minutes |
| Continuous Operation | 200kV/0.4A (80%) 24/7 |
| Dielectric Loss | <0.4% @ 250kV |
| Short-circuit Withstand | 300% for 2 seconds |
Thermal Management
Winding ΔT: ≤65K at full load
Oil ΔT: ≤55K under maximum load
Dual cooling systems:
Natural convection (base cooling)
Forced oil circulation (15m³/hour)
Integrated oil temperature control (40-70°C range)
Insulation System
| Component | Test Voltage |
|---|---|
| LV Winding-Ground | 3kV/1min |
| HV Winding-Ground | 3kV/1min |
| Inter-winding | 3× rated voltage |
Mechanical Construction
Reinforced steel tank (12mm walls) with corrosion coating
Vibration-damped core assembly (2Hz natural frequency)
Modular HV bushing design (replaceable without oil drainage)
Integrated wheels with 5-ton capacity
Safety & Compliance
IEC 60076-1 (Power Transformers)
IEEE C57.12.90 (Test Code)
EN 50588 (Industrial Applications)
Dual Buchholz relays with alarm/trip contacts
Industrial Applications
EHV cable system factory tests
Power transformer impulse testing
High-energy capacitor bank verification
Industrial coating system power supplies
Research facility high-power experiments
With its 125kVA capacity and 0.5A output current, the HCTT-250kV transformer enables testing of ultra-high capacitance loads (up to 6,600pF at 250kV). The heavy-duty design ensures reliable operation in continuous industrial testing environments.