Charging Transformer
HCTT-240kV/1.67A High-Current Charging Transformer
Product Overview
The HCTT-240kV/1.67A represents the pinnacle of high-current HV testing technology, combining 400kVA capacity with exceptional 1.67A output current and ≤5pC partial discharge performance for large-scale test applications.
Technical Specifications
Electrical Parameters | |
---|---|
Rated Capacity | 400kVA (±1.5%) |
Input Voltage | 600V 3-phase ±5% (Exciting Winding) |
Output Voltage | 240kV DC/AC (HV Winding) |
Current Ratings | 666.7A (Input) / 1.67A (Output) |
Frequency | 50Hz ±0.1% (synchronized grid operation) |
Measurement Precision | ±0.1% via 1000:1 ratio winding |
Performance Characteristics
Key Metrics
Partial Discharge: ≤5pC @ 240kV, ≤3pC @ 192kV
No-load Current: ≤10% of rated current
Waveform Distortion: ≤5% THD at full load
Current Stability: ±0.5% over 8-hour operation
Robust Design Features
Capability | Specification |
---|---|
Over-current | 150% (2.5A) for 5 minutes |
Over-voltage | 264kV (110%) for 60 seconds |
Continuous Operation | 192kV/1.34A (80%) 24/7 |
Dielectric Strength | 3kV/min (LV-HV-Ground) |
Partial Discharge Control
Quadruple-shielded pancake winding design
Gas-insulated HV bushing (SF6 alternative available)
On-line oil degassing system (≤10ppm moisture)
All internal edges radiused (R10 minimum)
Thermal Management
Winding ΔT: ≤65K at 1.67A continuous
Oil ΔT: ≤55K under maximum load
Three-stage cooling system:
Natural convection (base load)
Forced oil circulation (12m³/hr)
Water-assisted cooling (optional)
Insulation System
Component | Withstand Voltage |
---|---|
LV Winding | 3kV/1min to ground |
HV Winding | 3kV/1min to ground |
Inter-winding | 4× rated voltage |
Mechanical Design
Modular tank construction (15mm steel walls)
Vibration-isolated core (1Hz natural frequency)
Quick-disconnect HV terminal (5-minute changeout)
Cleanroom assembly (Class 100)
Compliance Standards
IEC 62067 (Cable Test Systems)
IEEE C57.152 (PD Measurement Guide)
EN 50581 (Industrial HV Equipment)
ASTM D924 (Dielectric Loss Test)
Industrial Applications
Extra High Voltage (EHV) cable testing
GIS (Gas Insulated Substation) commissioning
High-current partial discharge research
Pulsed power system development
Supergrid equipment verification
With its unprecedented 1.67A output current at 240kV, the HCTT transformer enables testing of ultra-high capacitance loads (up to 11,000pF). The ≤5pC partial discharge level maintains measurement integrity even in sensitive high-current test environments.