800KV/30pF SF6 Ultra-HV Divider | Wide-Frequency (30-300Hz) Measurement with 4000:1 Ratio

Precision 800KV/30pF SF6 gas-insulated voltage divider featuring 30-300Hz wide-frequency operation, 4000:1 ratio, and 180-minute continuous duty cycle for UHV transmission systems.


  • US$1.00; Negotiated Price
  • Lead time: 120days

>>>WhatsApp Communication<<<

Product Details

Product Tags

800KV/30pF SF6 Capacitor Voltage Divider

This ultra-high voltage measurement device delivers unprecedented wide-band performance for 800KV-class transmission systems, combining 4000:1 high-ratio measurement with extended 180-minute operation capability.

Technical Specifications

ParameterSpecificationTechnical Significance
Rated Voltage800KVDesigned for 765KV systems with 4.6% margin
Frequency Range30-300HzFrom sub-harmonic to 6th harmonic analysis
Voltage Ratio4000:1200V output at rated voltage
Capacitance30pFUltra-low loading (0.075mA at 800KV)
Accuracy≤±1%Class 1 measurement precision
Dielectric Loss<0.5%Excellent insulation efficiency
Duty Cycle180min ON/60min OFFExtended continuous operation

Breakthrough Features

Wide-Frequency Technology

  • 30Hz for sub-synchronous resonance studies

  • 50/60Hz fundamental power measurements

  • Up to 300Hz (6th harmonic) analysis

  • Flat frequency response (±0.2dB)

Thermal Management System

  • Optimized gas flow design

  • Distributed temperature sensors

  • 180-minute continuous rating

  • 60-minute cooldown period

Typical Applications

UHV Transmission

  • 765KV line voltage monitoring

  • Power quality analysis

Research Facilities

  • Sub-synchronous oscillation studies

  • Harmonics measurement up to 300Hz

Converter Stations

  • HVDC valve-side measurements

  • Characteristic harmonic analysis

Installation Requirements

  1. Climate-controlled environment (±2°C)

  2. Maintain SF6 pressure at 0.70±0.02MPa (20°C)

  3. Use low-noise triaxial cables (min 12mm diameter)

  4. Grounding resistance <0.5Ω (measured at DC)

  5. Minimum clearances:

    • 7m to grounded objects

    • 10m to other HV equipment

Maintenance Protocol

IntervalProcedureAcceptance Criteria
Pre-operationGas purity testSF6 ≥99.95%
DailyPressure verification0.68-0.72MPa
WeeklyFrequency response test30-300Hz ±0.2dB
MonthlyRatio accuracy check4000:1 ±0.5%

Compliance Standards

  • IEC 60060-1:2010 (High-voltage test techniques)

  • IEEE Std 4-2013 (Standard for HV testing)

  • IEC 61869-11:2018 (Instrument transformers)

  • GB/T 16927.1-2011 (Chinese HV test standards)

Critical Requirement: Requires ≥50MΩ input impedance measuring instruments due to 30pF capacitance. Strictly observe 60-minute cooldown after 180-minute operation.

>>>WhatsApp Communication<<<