High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

Gas Insulated Divider

750KV/300pF SF6 Hybrid Capacitor: Ultra-HV Divider & Coupling System with <5pC PD

Industrial-grade 750KV/300pF SF6-insulated dual-role device combining precision voltage measurement (±1% accuracy) with power line coupling, featuring <5pC partial discharge and 15-minute continuous operation.


  • US$1.00; Negotiated Price
  • Lead time: 120days

>>>WhatsApp Communication<<<

Product Details

Product Tags

750KV/300pF SF6 Hybrid Capacitor Voltage Divider & Coupling System

This ultra-high voltage hybrid device delivers dual functionality for 800KV-class systems, combining precision measurement with power line communication capabilities in a single SF6-insulated unit with exceptional <5pC partial discharge performance.

Technical Specifications

ParameterSpecificationEngineering Benefit
Rated Voltage750KVDesigned for 800KV systems with 6.25% margin
Capacitance300pFOptimal balance for measurement & PLC coupling
Frequency50HzStandard power frequency operation
Voltage Ratio2000:1375V output at rated voltage
Accuracy≤±1%Class 1 measurement precision
Partial Discharge<5pC @750KV
<3pC @600KV
Superior PD performance for EHV systems
Dielectric Loss<0.3%Minimal signal attenuation
Temp Coefficient<0.0005Stable across -40°C to +85°C
Overvoltage825KV for 60s110% rated voltage withstand
Operation Time15 minutes continuousThermally optimized duty cycle

Dual-Role Performance

As Voltage Divider

  • 2000:1 ratio for EHV protection systems

  • ±1% accuracy meets metering-class requirements

  • Ultra-low <5pC partial discharge

As Coupling Capacitor

  • 300pF optimized for carrier signal injection

  • Low-loss design maximizes PLC efficiency

  • Integrated solution reduces substation footprint

PD Control Technology

  • Quad-Shield Electrodes: Four-stage grading rings

  • Superfinish Surfaces: Mirror polish (Ra<0.3μm)

  • Gas Purity System: Active SF6 filtration

  • Thermal Management: 15-minute operation limit prevents gas overheating

Installation Requirements

  1. Vibration-isolated foundation (max 0.05g)

  2. Maintain SF6 pressure at 0.68±0.02MPa (20°C)

  3. Measurement connections:

    • Triple-shielded coaxial cables

    • Minimum 10mm conductor diameter

  4. Clearance distances:

    • 6m to grounded structures

    • 9m to other HV equipment

Maintenance Schedule

IntervalProcedureAcceptance Criteria
Pre-operationGas density check0.66-0.70MPa
WeeklySurface inspectionNo visible contamination
MonthlyPartial discharge test<5pC @750KV
QuarterlyCapacitance verification300pF ±2%

Compliance Standards

  • IEC 60060-1:2010 (High-voltage test techniques)

  • IEC 60358-1:2012 (Coupling capacitors/dividers)

  • IEEE C93.3-2020 (Power line carrier coupling)

  • GB/T 4109-2020 (Chinese HV capacitor standards)

Critical Notice: The 15-minute operation limit must be strictly observed to prevent SF6 gas decomposition. Allow 45 minutes cooling after each operation cycle.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<