540KV/30pF Ultra-High Voltage Divider with <3pC Partial Discharge | SF6 Gas-Insulated Precision Instrument

Precision 540KV/30pF SF6 gas-insulated voltage divider featuring industry-leading <3pC partial discharge, ±1% accuracy, and 60-minute continuous operation for extra-high voltage testing applications.


  • US$1.00; Negotiated Price
  • Lead time: 120days

>>>WhatsApp Communication<<<

Product Details

Product Tags

540KV/30pF SF6 Gas-Insulated Capacitor Voltage Divider

This ultra-high voltage measurement device sets new benchmarks in partial discharge performance, designed for precision measurements in 500KV-class transmission systems and high-voltage laboratories.

Technical Specifications

ParameterSpecificationPerformance Significance
Rated Voltage540KVDesigned for 500KV systems with 8% margin
Rated Capacity30pFUltra-low circuit loading
Frequency Range45-65HzCovers power frequency variations
Dividing Ratio2000:1High-ratio measurement for EHV systems
Accuracy≤±1%Class 1 measurement precision
Partial Discharge<3pC @540KV
<2pC @432KV
Industry-leading PD performance
Dielectric Loss<0.3%Exceptional insulation efficiency
Temp Coefficient<0.0005Stable across -40°C to +85°C
Overvoltage594KV for 60s110% rated voltage withstand
Operation Time60 minutes continuousExtended testing capability

Breakthrough PD Performance

Advanced Corona Suppression

  • Triple-shield electrode design

  • Ultra-smooth surface finish (Ra<0.8μm)

  • SF6 gas purification system

Measurement Advantages

  • Enables sensitive PD measurements in noisy environments

  • Allows detection of sub-3pC insulation defects

  • Maintains signal integrity for harmonics analysis

Typical Applications

EHV Transmission

  • 500KV line voltage monitoring

  • Grid synchronization measurements

High Voltage Labs

  • Reference standard for calibrations

  • Ultra-low PD testing

Transformer Testing

  • Applied voltage measurements

  • Partial discharge localization

Installation Requirements

  1. Install in controlled environment (temperature variation <5°C/hour)

  2. Maintain SF6 pressure at 0.55±0.03MPa (at 20°C)

  3. Use triple-shielded coaxial cables (minimum 10mm diameter)

  4. Grounding system resistance <1Ω (measured at DC)

  5. Minimum clearance distances:

    • 3m to grounded objects

    • 5m to other HV equipment

Maintenance Schedule

IntervalProcedureAcceptance Criteria
DailyGas density check0.52-0.58MPa
WeeklySurface inspectionNo visible contamination
MonthlyPartial discharge test<3pC @540KV
AnnuallyFull calibrationRatio error ≤±0.5%

Compliance Standards

  • IEC 60060-1:2010 (High-voltage test techniques)

  • IEC 60270:2015 (Partial discharge measurements)

  • IEEE Std 4-2013 (Standard for HV testing)

  • GB/T 16927.1-2011 (Chinese HV test standards)

Critical Notice: Requires minimum 10MΩ input impedance measuring instruments to maintain specified accuracy with 30pF capacitance. Never exceed 60 minutes continuous operation at rated voltage.