Gas Insulated Divider
540KV/30pF SF6 Gas-Insulated Capacitor Voltage Divider
This ultra-high voltage measurement device sets new benchmarks in partial discharge performance, designed for precision measurements in 500KV-class transmission systems and high-voltage laboratories.
Technical Specifications
Parameter | Specification | Performance Significance |
---|---|---|
Rated Voltage | 540KV | Designed for 500KV systems with 8% margin |
Rated Capacity | 30pF | Ultra-low circuit loading |
Frequency Range | 45-65Hz | Covers power frequency variations |
Dividing Ratio | 2000:1 | High-ratio measurement for EHV systems |
Accuracy | ≤±1% | Class 1 measurement precision |
Partial Discharge | <3pC @540KV <2pC @432KV | Industry-leading PD performance |
Dielectric Loss | <0.3% | Exceptional insulation efficiency |
Temp Coefficient | <0.0005 | Stable across -40°C to +85°C |
Overvoltage | 594KV for 60s | 110% rated voltage withstand |
Operation Time | 60 minutes continuous | Extended testing capability |
Breakthrough PD Performance
Advanced Corona Suppression
Triple-shield electrode design
Ultra-smooth surface finish (Ra<0.8μm)
SF6 gas purification system
Measurement Advantages
Enables sensitive PD measurements in noisy environments
Allows detection of sub-3pC insulation defects
Maintains signal integrity for harmonics analysis
Typical Applications
EHV Transmission
500KV line voltage monitoring
Grid synchronization measurements
High Voltage Labs
Reference standard for calibrations
Ultra-low PD testing
Transformer Testing
Applied voltage measurements
Partial discharge localization
Installation Requirements
Install in controlled environment (temperature variation <5°C/hour)
Maintain SF6 pressure at 0.55±0.03MPa (at 20°C)
Use triple-shielded coaxial cables (minimum 10mm diameter)
Grounding system resistance <1Ω (measured at DC)
Minimum clearance distances:
3m to grounded objects
5m to other HV equipment
Maintenance Schedule
Interval | Procedure | Acceptance Criteria |
---|---|---|
Daily | Gas density check | 0.52-0.58MPa |
Weekly | Surface inspection | No visible contamination |
Monthly | Partial discharge test | <3pC @540KV |
Annually | Full calibration | Ratio error ≤±0.5% |
Compliance Standards
IEC 60060-1:2010 (High-voltage test techniques)
IEC 60270:2015 (Partial discharge measurements)
IEEE Std 4-2013 (Standard for HV testing)
GB/T 16927.1-2011 (Chinese HV test standards)
Critical Notice: Requires minimum 10MΩ input impedance measuring instruments to maintain specified accuracy with 30pF capacitance. Never exceed 60 minutes continuous operation at rated voltage.