200kV ~ 400kV Range
LQHVF 250kV/12500pF Capacitor Voltage Divider: Temperature-Stable Precision for Critical Measurements
Advanced HV Measurement with Unmatched Stability
The LQHVF 250kV/12500pF capacitor voltage divider sets a new standard for measurement consistency with its revolutionary temperature-compensated design. Engineered for laboratory-grade accuracy in field conditions, this solution delivers:
Ultra-low dielectric loss (<0.2%) for precise insulation assessment
Temperature-stable divider ratio (1000:1) across operating range
Mobile deployment capability with integrated casters
275kV insulation withstand for maximum reliability
Breakthrough Thermal Stability
Identical medium in HV/LV arms maintains ≤0.1% ratio variance across -20°C to +50°C range - eliminating measurement drift during extended tests.
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 250kV | EHV transmission system testing |
Rated Capacitance | 12500pF | High-current measurement capability |
Accuracy | ≤ ±1% | Exceeds IEC 60060-2 Class 0.5 |
Dielectric Loss | <0.2% | Industry's lowest loss for insulation diagnostics |
Insulation Level | HV Arm: 275kV/1min LV Arm: 3kV/1min | Enhanced safety margin |
Frequency | 50Hz | Power system fundamental frequency |
Patented Design Features
Epoxy Oil-Paper Insulation
Tube-shell structure with low-temperature-coefficient material ensures stable capacitance across thermal cycles.
Mobile Base with Casters
Industrial-grade casters with locking mechanism enable repositioning without disassembly.
Identical Arm Medium
HV/LV arms use same dielectric material to maintain 1000:1 ratio during temperature fluctuations.
Quick-Disconnect Structure
Modular design dismantles for transport and reassembles in<20 minutes.="">
Thermal Stability Verification
Rigorous Testing Protocol
Each unit undergoes temperature cycling with capacitance and tanδ measurements at:
Ambient temperature (25°C) baseline
-20°C after 4-hour stabilization
+50°C after 4-hour stabilization
Certified ratio variation<0.1% across="" full="" temperature="" range.="">
Operational Advantages
Unmatched Measurement Stability:
<0.1% ratio="" drift="" in="" varying="" environments="">Ultra-Low Loss Diagnostics:
<0.2% tan="">True Mobility: 360° rotating casters with 500kg load capacity
Safety Assurance: Dual insulation levels (275kV HV / 3kV LV)
"The temperature stability eliminates recalibration during day-long tests - we've reduced measurement uncertainty by 60% in outdoor substations."
- Chief Test Engineer, National Power Laboratory
Field Deployment Protocol
Transport: Lock casters during movement on uneven surfaces
Positioning: Deploy on level surfaces (max 3° incline)
Pre-Test Verification:
Measure capacitance at ambient temperature
Verify tanδ
<0.2%<>Insulation Check: Perform 3kV/1min test on LV arm
Operation: Monitor base stability during 250kV tests
Post-Test: Measure capacitance/tanδ to confirm stability
Compliance & Certifications
Third-party validated to international standards:
IEC 60060-1/2: High-voltage test techniques
IEC 60270: Partial discharge measurements
IEEE 4: Standard for HV testing
ASTM D924: Standard test method for dissipation factor
Includes NIST-traceable temperature stability certification.