High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

200kV ~ 400kV Range

Ultra-Stable 250kV/12500pF Capacitor Voltage Divider | Temperature-Compensated Precision

250kV/12500pF capacitor voltage divider with <0.2% dielectric loss and ≤1% accuracy. Features temperature-compensated design, mobile base with casters, and 275kV insulation for reliable power system testing.


  • US$ 7,157.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 250kV/12500pF Capacitor Voltage Divider: Temperature-Stable Precision for Critical Measurements

Advanced HV Measurement with Unmatched Stability

The LQHVF 250kV/12500pF capacitor voltage divider sets a new standard for measurement consistency with its revolutionary temperature-compensated design. Engineered for laboratory-grade accuracy in field conditions, this solution delivers:

  • Ultra-low dielectric loss (<0.2%) for precise insulation assessment

  • Temperature-stable divider ratio (1000:1) across operating range

  • Mobile deployment capability with integrated casters

  • 275kV insulation withstand for maximum reliability

Breakthrough Thermal Stability

Identical medium in HV/LV arms maintains ≤0.1% ratio variance across -20°C to +50°C range - eliminating measurement drift during extended tests.

Technical Specifications

ParameterSpecificationPerformance Advantage
Rated Voltage250kVEHV transmission system testing
Rated Capacitance12500pFHigh-current measurement capability
Accuracy≤ ±1%Exceeds IEC 60060-2 Class 0.5
Dielectric Loss<0.2%Industry's lowest loss for insulation diagnostics
Insulation LevelHV Arm: 275kV/1min
LV Arm: 3kV/1min
Enhanced safety margin
Frequency50HzPower system fundamental frequency

Patented Design Features

Epoxy Oil-Paper Insulation

Tube-shell structure with low-temperature-coefficient material ensures stable capacitance across thermal cycles.

Mobile Base with Casters

Industrial-grade casters with locking mechanism enable repositioning without disassembly.

Identical Arm Medium

HV/LV arms use same dielectric material to maintain 1000:1 ratio during temperature fluctuations.

Quick-Disconnect Structure

Modular design dismantles for transport and reassembles in<20 minutes.="">

Thermal Stability Verification

Rigorous Testing Protocol

Each unit undergoes temperature cycling with capacitance and tanδ measurements at:

  1. Ambient temperature (25°C) baseline

  2. -20°C after 4-hour stabilization

  3. +50°C after 4-hour stabilization

Certified ratio variation<0.1% across="" full="" temperature="" range.="">

Operational Advantages

  • Unmatched Measurement Stability:

    <0.1% ratio="" drift="" in="" varying="" environments="">
  • Ultra-Low Loss Diagnostics:

    <0.2% tan="">
  • True Mobility: 360° rotating casters with 500kg load capacity

  • Safety Assurance: Dual insulation levels (275kV HV / 3kV LV)

"The temperature stability eliminates recalibration during day-long tests - we've reduced measurement uncertainty by 60% in outdoor substations."
               - Chief Test Engineer, National Power Laboratory

Field Deployment Protocol

  1. Transport: Lock casters during movement on uneven surfaces

  2. Positioning: Deploy on level surfaces (max 3° incline)

  3. Pre-Test Verification:

    • Measure capacitance at ambient temperature

    • Verify tanδ

      <0.2%<>
  4. Insulation Check: Perform 3kV/1min test on LV arm

  5. Operation: Monitor base stability during 250kV tests

  6. Post-Test: Measure capacitance/tanδ to confirm stability

Compliance & Certifications

Third-party validated to international standards:

  • IEC 60060-1/2: High-voltage test techniques

  • IEC 60270: Partial discharge measurements

  • IEEE 4: Standard for HV testing

  • ASTM D924: Standard test method for dissipation factor

Includes NIST-traceable temperature stability certification.

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message