>400kV Range
LQHDR Series: 800kV/5kΩ High-Power Damping Resistor
Engineered for extreme high-voltage/high-current applications, this 20kW damping resistor sets new standards for PD performance and thermal management in critical test systems.
Technical Specifications
Parameter | Specification |
---|---|
Rated Voltage | 800kV AC/DC |
Nominal Resistance | 5kΩ ±0.8% |
Rated Current | 2A continuous |
Rated Power | 20kW at 50Hz |
Partial Discharge (PD) Level | <2pC at rated voltage |
Operating Duration | 60 minutes at 100% rated voltage/current |
Temperature Rise | <120K at continuous 100% load |
Performance Highlights
Industry-Leading PD Performance
Ultra-low <2pC partial discharge level at 800kV ensures precision measurements during dielectric tests, exceeding IEC 60270 Class I requirements.
High-Current Capability
2A continuous current rating enables testing of high-energy systems previously requiring multiple parallel resistors.
Advanced Thermal Design
Optimized heat dissipation maintains surface temperature rise below 120K at full 20kW load, featuring:
Forced-air cooling channels
High-thermal-conductivity materials
Temperature-monitored hot spots
Structural Features
Robust Construction: Nickel-chromium alloy resistance elements on ceramic-insulated cores
Multi-Point Shielding: Triple corona rings minimize discharge interference
Modular Design: Stackable sections for transportation and maintenance
EMI Suppression: Integrated Faraday cage elements
Industrial Applications
Ultra-high-voltage transformer impulse testing
HVDC converter station commissioning
Nuclear fusion research equipment
High-power laboratory test systems (>15MW)
Transmission line surge arrestor validation
Safety & Compliance
IEC 60060-1:2010 High-voltage test techniques
IEEE 4-2013 Standard for HV testing
EN 50191:2010 Erection and operation of electrical test equipment
Certified for 900kV power frequency withstand (1 minute)
Installation Requirements
Minimum 3.5m clearance to grounded structures
Dedicated 200A cooling system power supply
Ambient temperature ≤35°C during operation
Monthly IR thermography scans recommended
Calibration every 6 months or 50 operations
Power Derating Guidelines
Ambient Temperature | Maximum Continuous Power |
---|---|
≤25°C | 100% (20kW) |
30°C | 18kW |
35°C | 15kW |