High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>400kV Range

LQHDR 1000kV/5kΩ/0.5A Damping Resistor: Precision Performance with Enhanced Current Capacity

Technical specifications for the LQHDR 1000kV/5kΩ/0.5A damping resistor featuring ≤5pC partial discharge, 100K max temperature rise, and 1.25kW power rating.


  • Negotiated Price
  • Lead time: 60days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR 1000kV/5kΩ/0.5A Enhanced-Current Damping Resistor

Electrical Specifications

ParameterSpecificationStandard
Rated Voltage1000kV ACIEC 60273
Nominal Resistance5kΩ ±0.2%IEEE 4-2013
Rated Current0.5A continuousIEC 60076
Power Rating1.25kWThermal Class B
Frequency50HzIEC 60060-1

Partial Discharge Performance

  • ≤5pC at 100% rated voltage (1000kV)

  • ≤2pC at 80% rated voltage (800kV)

  • Tested per IEC 60270 with EMI-shielded chamber

Ultra-low discharge characteristics ensure measurement accuracy in sensitive high-voltage circuits.

Thermal Management & Operation

Continuous Operation: 60 minutes at:

  • 100% rated voltage (1000kV)

  • 100% rated current (0.5A)

  • Full power dissipation (1.25kW)

Temperature Rise: ≤100K after 60 minutes continuous operation

Enhanced Current Capability

  • 50% higher current capacity than standard models (0.5A vs 0.3A)

  • Maintains ±0.1% resistance stability at full load

  • Optimized for extended test cycles in calibration systems

Precision Engineering Features

  • Low TCR: 3ppm/°C temperature coefficient

  • Voltage Coefficient:

    <0.0005%>
  • Construction: Vacuum-impregnated manganin windings

  • Thermal Path: Copper-beryllium heat spreaders

Critical Applications

  • High-voltage calibrator reference circuits

  • Partial discharge measurement systems

  • UHV transformer diagnostic equipment

  • National metrology laboratory standards

  • Dielectric response analyzers

Thermal Performance Data

Load ConditionSurface ΔTStabilization Time
100% rated power≤100K35 minutes
80% rated power≤75K28 minutes
50% rated power≤40K20 minutes

Operational Protocols

  1. Pre-operation resistance verification (±0.05% tolerance)

  2. Ambient stabilization at 23°C ±1°C

  3. Maximum 60-minute continuous operation cycles

  4. 90-minute cooldown between full-power tests

Compliance & Certification

  • IEC 60273: High-voltage resistors

  • IEEE 4-2013: HV testing standards

  • ISO/IEC 17025: Calibration requirements

  • EN 61326-1: EMC for measurement equipment

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message