>400kV Range
LQHDR 1000kV/5kΩ/0.5A Enhanced-Current Damping Resistor
Electrical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 1000kV AC | IEC 60273 |
Nominal Resistance | 5kΩ ±0.2% | IEEE 4-2013 |
Rated Current | 0.5A continuous | IEC 60076 |
Power Rating | 1.25kW | Thermal Class B |
Frequency | 50Hz | IEC 60060-1 |
Partial Discharge Performance
≤5pC at 100% rated voltage (1000kV)
≤2pC at 80% rated voltage (800kV)
Tested per IEC 60270 with EMI-shielded chamber
Ultra-low discharge characteristics ensure measurement accuracy in sensitive high-voltage circuits.
Thermal Management & Operation
Continuous Operation: 60 minutes at:
100% rated voltage (1000kV)
100% rated current (0.5A)
Full power dissipation (1.25kW)
Temperature Rise: ≤100K after 60 minutes continuous operation
Enhanced Current Capability
50% higher current capacity than standard models (0.5A vs 0.3A)
Maintains ±0.1% resistance stability at full load
Optimized for extended test cycles in calibration systems
Precision Engineering Features
Low TCR: 3ppm/°C temperature coefficient
Voltage Coefficient:
<0.0005%>Construction: Vacuum-impregnated manganin windings
Thermal Path: Copper-beryllium heat spreaders
Critical Applications
High-voltage calibrator reference circuits
Partial discharge measurement systems
UHV transformer diagnostic equipment
National metrology laboratory standards
Dielectric response analyzers
Thermal Performance Data
Load Condition | Surface ΔT | Stabilization Time |
---|---|---|
100% rated power | ≤100K | 35 minutes |
80% rated power | ≤75K | 28 minutes |
50% rated power | ≤40K | 20 minutes |
Operational Protocols
Pre-operation resistance verification (±0.05% tolerance)
Ambient stabilization at 23°C ±1°C
Maximum 60-minute continuous operation cycles
90-minute cooldown between full-power tests
Compliance & Certification
IEC 60273: High-voltage resistors
IEEE 4-2013: HV testing standards
ISO/IEC 17025: Calibration requirements
EN 61326-1: EMC for measurement equipment