High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>400kV Range

LQHDR 750kV/5kΩ/0.5A Damping Resistor | High-Voltage Test Component | Honeycomb Cooling Design

Technical specifications for LQHDR 750kV/5kΩ damping resistor with honeycomb cooling structure, shielding rings, and 60-min operation at full load.


  • Negotiated Price
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series: 750kV/5kΩ High-Voltage Damping Resistor

Advanced damping resistor engineered for ultra-high-voltage testing applications featuring innovative thermal management and discharge protection.

Technical Specifications

ParameterSpecification
Rated Voltage750kV AC/DC
Nominal Resistance5kΩ ±1%
Rated Current0.5A continuous
Frequency50Hz
Maximum Operating Duration60 minutes at 100% rated voltage/current
Temperature Rise<100K at continuous 100% load

Innovative Structural Design

Honeycomb Thermal Management

Nickel-chromium resistance wire precision-wound on epoxy boards in honeycomb configuration delivers:

  • Optimal air-thermal exchange for efficient cooling

  • Prevention of resistance degradation under thermal stress

  • Uniform temperature distribution across resistor body

  • Material strength preservation at high temperatures

Triple-Shielding Ring Protection

Strategic shielding rings at both ends and center provide:

  • Complete discharge path isolation during test failures

  • Insulation damage prevention

  • Electromagnetic interference (EMI) suppression

  • Corona discharge minimization

Performance Features

  • Thermal Stability: Maintains <100K temperature rise at 750kV/0.5A for 60 minutes

  • Material Integrity: Nickel-chromium alloy ensures consistent resistance values at high temperatures

  • Structural Reliability: Epoxy-wound construction withstands mechanical stress during transients

  • Voltage Endurance: Certified performance at 750kV without flashover

Critical Applications

  • Impulse voltage generator circuits

  • Ultra-high-voltage transformer testing

  • GIS (Gas-Insulated Switchgear) partial discharge measurement

  • HVDC transmission system commissioning

  • High-power laboratory test systems

Installation & Safety Protocols

  1. Maintain minimum 3-meter clearance to grounded surfaces

  2. Install exclusively in vertical orientation

  3. Ensure ambient temperature ≤40°C during operation

  4. Verify shield ring continuity before energizing

  5. Perform dielectric verification test after installation

Complies with international standards: IEC 60060-1, IEEE 4, and IEC 60270.

Technical Advantages

FeatureBenefit
Honeycomb Structure40% better heat dissipation vs conventional designs
Nickel-Chromium Wire±0.5% resistance stability at 500°C
Triple Shielding RingsEliminates insulation damage during 500kJ discharges
Epoxy Board BaseHigh mechanical strength with CTI >600V

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message