<100kV Range
LQHVF 70kV/500pF Oil-Immersed Capacitor Voltage Divider
Compact high-voltage measurement solution featuring exceptional thermal stability and ultra-low partial discharge. Engineered for precision in power transmission testing, substation monitoring, and laboratory calibration.
Technical Specifications
Rated Voltage: 70kV AC RMS
Nominal Capacitance: 500pF (+5%/-10%)
Dividing Ratio: 1000:1 (±1% accuracy)
Frequency Range: 50/60Hz (30-800Hz optional)
Dielectric Loss: <0.3% @ 25°C
Partial Discharge: <5pC at 70kV
Temperature Coefficient: <80 × 10-6 pF/°C
Cooling System: ONAN (Oil Natural Air Natural)
Operating Duration:
60 minutes continuous @ 100% rated voltage
Unlimited operation @ 80% rated voltage
Advanced Structural Design
Oil-Immersed Modular Architecture
Dielectric fluid encapsulation ensures thermal stability and arc suppression. Removable components enable field servicing without specialized tools:
Corona Rings: Dual-ring configuration prevents ionization at HV terminals
LY Arm: Low-voltage interface with shielded BNC connectors
HV Arm: Capacitive stack with graded field control
Removable Base: Facilitates oil maintenance and component inspection
Compact Footprint
Dimensions: 400mm × 400mm × 1000mm (W×D×H)
Weight: <35kg (transportable by two technicians)
Mounting: Dual M12 anchor points for permanent/portable installation
Performance Validation Metrics
Parameter | Test Standard | Guaranteed Performance |
---|---|---|
Voltage Withstand | IEC 60060-1 | 84kV/1min (120% rated voltage) |
Temperature Stability | IEC 60270 | ±0.5% capacitance shift (-25°C to +55°C) |
Partial Discharge | IEC 60270 | <3pC @ 80% rated voltage |
Industrial Applications
Power Transmission
Switchgear commissioning
Transformer ratio verification
Harmonic distortion analysis
Renewable Energy
Solar farm combiner monitoring
Wind turbine step-up transformers
Battery isolation testing
Research & Development
Dielectric material testing
Partial discharge studies
High-frequency impulse measurement
Operational Advantages
Ultra-Low Loss: <0.3% dielectric loss ensures measurement accuracy in energy-critical applications
Thermal Stability: Minimal capacitance drift (±0.002%/°C) across operating range
Maintenance Optimized: Removable base reduces service downtime by 70% vs sealed units
Safety Compliance: Double-insulated design meets IEC 61010 CAT IV requirements
Environmental Specifications
Operating Temperature: -25°C to +55°C
Altitude Rating: 3000m ASL
Humidity: 0-95% non-condensing
Cooling: Natural convection (no fans/blowers required)