High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

<100kV Range

LQHVF 70kV/300pF Oil-Immersed Capacitor Voltage Divider | Precision HV Measurement

Precision LQHVF 70kV/300pF oil-immersed capacitor voltage divider with 1000:1 ratio, <3pC partial discharge, and ONAN cooling. Ideal for switchgear testing, power quality monitoring, and HV labs. Compliant with IEC 60060 standards.


  • US$ 2,221.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 70kV/300pF Oil-Immersed Capacitor Voltage Divider

Precision high-voltage measurement solution for switchgear testing, substation monitoring, and power quality analysis. Combines IEC-compliant accuracy with modular serviceability.

Technical Specifications

  • Rated Voltage: 70kV AC RMS

  • Nominal Capacitance: 300pF ±5%

  • Dividing Ratio: 1000:1 (±1% accuracy)

  • Frequency: 50/60Hz (40-500Hz customizable)

  • Dielectric Loss: <0.5% @ 20°C

  • Partial Discharge (PD): <3pC at 70kV

  • Cooling System: ONAN (Oil Natural Air Natural)

  • Operating Time:

    • 60 mins continuous @ 100% rated voltage

    • Unlimited operation @ 80% rated voltage

Structural Advantages

Oil-Immersed Modular Design

Mineral oil insulation ensures thermal stability and arc suppression. Removable components enable field maintenance:

  • Corona Ring: Prevents ionization at HV terminals

  • LY Arm: Low-voltage measurement interface

  • HY Arm: High-voltage capacitive stack

  • Removable Base: Facilitates oil replacement and inspection

Performance Validation

ParameterTest ConditionPerformance
Temperature Rise70kV continuous 60-min operation<45°C above ambient
Linearity Error10-100% rated voltage<±0.8%
Phase Angle50Hz nominal load<5 minutes

Compliance: Meets IEC 60060-1, IEC 61869-11, and IEEE C57.13 standards.

Industrial Applications

Power Systems

Accurate voltage measurement in:

  • 33kV+ switchgear commissioning

  • Transformer ratio verification

  • Harmonic analysis in substations

Test Laboratories

Critical for:

  • Partial discharge detection systems

  • Dielectric withstand testing

  • Calibration reference standards

Safety & Maintenance Protocols

  1. Pre-Operation Check: Verify oil level indicators and grounding continuity

  2. Thermal Management: Maintain ambient temperature below 40°C for ONAN efficiency

  3. Calibration Cycle: Annual recertification recommended per ISO 17025

  4. PD Monitoring: Quarterly tests when used >50% rated voltage

Why Choose This HV Divider?

  • Ultra-Low PD: <3pC ensures measurement integrity in sensitive applications

  • Removable Design: 60% faster maintenance vs. sealed units

  • ONAN Cooling: Eliminates need for forced-air systems

  • Extended Duty Cycle: Industry-leading 60-min full-voltage operation

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message