<100kV Range
LQHVF 50kV/1000pF Capacitive Voltage Divider & Coupling Capacitor
Space-Optimized Design: Full 50kV capability in compact 300×300×600mm cube footprint with dual measurement functionality
High-Density HV Instrument for Constrained Spaces
Engineered for 50kV systems where space is critical, the LQHVF delivers laboratory-grade performance in a field-deployable cube design. The 1000pF capacitance enables:
Accurate voltage measurement with ≤±1% accuracy
Sensitive partial discharge detection (<5pC)
Harmonic analysis up to 20kHz bandwidth
Dielectric loss monitoring with <0.5% dissipation
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 50kV | Ultra-high voltage capability |
Capacitance | 1000pF | Optimal PD signal coupling |
Voltage Ratio | 1000:1 | 50V output at 50kV input |
Partial Discharge | <5pC @ 50kV | IEC 60270 Class I compliance |
Dielectric Loss | <0.5% | Superior insulation efficiency |
Dimensions (L×W×H) | 300×300×600mm | Compact substation footprint |
Weight | 15kg | Portable with carrying handles |
Operating Time | 60min @ 50kV | Full-power diagnostic capability |
L300mm
W300mm
H600mm
Modular Cube Design
Corona Ring
Aluminum alloy
Removable design
Ly Arm
Measurement interface
BNC output
Hy Arm
50kV terminal
Quick-disconnect
Removable Base
Stabilized platform
Leveling feet
Oil-Immersed Construction
Mineral oil dielectric for thermal management
Benefit: 40% better heat dissipation than air-cooled units
Quick-Disconnect System
Tool-free assembly in 8 minutes
Benefit: Rapid deployment in confined spaces
Dual-Function Operation
Voltage Division
Range: 0-50kV
Accuracy: ≤±1% at 50Hz
Output: 50V at 50kV input
PD Coupling
Sensitivity: <5pC at 50kV
Bandwidth: 20Hz-20kHz
Impedance: 80Ω at 2kHz
Space Advantage: The cube design provides 35% better space utilization than cylindrical dividers with equivalent rating, fitting switchgear compartments as small as 350×350×650mm.
Thermal Management
ONAN Cooling: Oil Natural Air Natural convection
Thermal Performance: <45°C rise during 60-min operation
Cooling Requirements: 20cm clearance on all sides
Operating Cycle: 60 minutes at 50kV followed by 60-minute cooldown
Compliance & Applications
Standards Compliance: IEC 60270:2000, IEEE 4-2013, EN 60060-1:2010
Space-Constrained Applications:
Switchgear compartments in compact substations
Mobile HV testing laboratories
Wind turbine nacelle testing
Underground power distribution systems
Shipboard electrical systems
Operational Protocol
Assembly
Secure base to stable surface
Connect Ly-arm to base
Install Hy-arm assembly
Attach corona ring
Connection
Ground base with ≥10mm² cable
Connect Ly-arm to voltmeter
For PD: Connect Hy-arm to analyzer
Operation
Ramp voltage gradually (≤5kV/s)
Max 60 minutes at 50kV
Ensure 20cm clearance maintained
Shutdown
De-energize system
Wait 10 minutes for discharge
Disassemble components
Pro Tip: In confined spaces, orient the cube with 600mm height vertical to maximize natural convection cooling
Why This Cube Design?
Space Efficiency
Fits compartments as small as 350×350×650mm
Full Capability
50kV performance in compact form
Modular Portability
15kg weight with removable components
Thermal Optimization
ONAN cooling in cube configuration