High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

400kV ~ 600kV Range

LQHVF 600kV/4000pF Coupling Capacitor & Voltage Divider | Ultra-HV Measurement Solution

Industrial-grade 600kV/4000pF coupling capacitor & capacitive voltage divider with ±1% accuracy, <5pC partial discharge, and ONAN cooling. IEC 60060-2 & IEEE 4 compliant for critical HV applications


  • US$ 13,704.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 600kV/4000pF Coupling Capacitor & Capacitive Voltage Divider

Precision high-voltage measurement solution designed for critical 50Hz applications requiring ±1% accuracy and ultra-low partial discharge performance. Compliant with IEC 60060-2 and IEEE 4 standards.

Technical Specifications

ParameterValueStandard
Rated Voltage600kV ACIEC 60060-1
Capacitance4000pF ±5%IEC 60358
Frequency50HzIEC 60076
Measuring Accuracy≤ ±1%IEEE 4-2013
Dielectric Loss (tanδ)< 0.2%IEC 60250
Partial Discharge< 5pC @ 600kV
< 2pC @ 500kV
IEC 60270
Dividing Ratio2000:1ANSI C92.2
Insulation Withstand660kV (110% rated) for 1minIEC 60060-2
Continuous Operation1 hour at rated voltageIEC 61462

Engineering Excellence Features

Advanced Corona Control

Precision-engineered aluminum alloy corona rings ensure:

  • Partial discharge <5pC at 600kV operation

  • Modular design for compact transportation

  • Corona-free HV connections

Thermal Management System

ONAN cooling technology delivers:

  • Continuous 1-hour operation at 600kV

  • Temperature stability within 45°C rise

  • IEC 60296 compliant insulating oil

Modular & Scalable Design

  • Removable stability pedestal with seismic rating

  • Special measuring lead-wire for VF sources (30-300Hz)

  • Supports single and two-stage serial configurations

Certifications & Safety Compliance

International Standards

  • IEC 60060-1/2: High-voltage test techniques

  • IEC 60270: Partial discharge measurements

  • IEEE 4: Standard for HV testing

  • ANSI C92.2: Capacitive voltage dividers

Safety Systems

  • Overvoltage automatic disconnect (660kV threshold)

  • Pressure-relief diaphragm for dielectric protection

  • Dual-point temperature monitoring

Industrial Applications

Power Transmission Systems

Precision measurement on 500kV+ transmission networks with IEEE C57.12.90 compliance

High-Power Test Labs

Extended test cycles at 600kV for transformer and breaker certification

Partial Discharge Research

Ultra-sensitive detection for GIS and cable systems with <2pC resolution

Technical FAQs

What calibration certificates are provided?

Each unit includes NIST-traceable calibration certificates for:

  • Dividing ratio accuracy (±0.5%)

  • Partial discharge sensitivity

  • Temperature-rise validation

Can this system measure impulse voltages?

Designed for 50Hz AC applications. For impulse testing (1.2/50μs), we recommend our LQHVF-IMP series with 1000kV BIL rating.

What is the recommended maintenance schedule?

Based on IEC 61462:

  • Dielectric oil testing: Annually

  • Full calibration: Every 2 years

  • Corona ring inspection: After transport

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message