400kV ~ 600kV Range
LQHVF 600kV/4000pF Coupling Capacitor & Capacitive Voltage Divider
Precision high-voltage measurement solution designed for critical 50Hz applications requiring ±1% accuracy and ultra-low partial discharge performance. Compliant with IEC 60060-2 and IEEE 4 standards.
Technical Specifications
Parameter | Value | Standard |
---|---|---|
Rated Voltage | 600kV AC | IEC 60060-1 |
Capacitance | 4000pF ±5% | IEC 60358 |
Frequency | 50Hz | IEC 60076 |
Measuring Accuracy | ≤ ±1% | IEEE 4-2013 |
Dielectric Loss (tanδ) | < 0.2% | IEC 60250 |
Partial Discharge | < 5pC @ 600kV < 2pC @ 500kV | IEC 60270 |
Dividing Ratio | 2000:1 | ANSI C92.2 |
Insulation Withstand | 660kV (110% rated) for 1min | IEC 60060-2 |
Continuous Operation | 1 hour at rated voltage | IEC 61462 |
Engineering Excellence Features
Advanced Corona Control
Precision-engineered aluminum alloy corona rings ensure:
Partial discharge <5pC at 600kV operation
Modular design for compact transportation
Corona-free HV connections
Thermal Management System
ONAN cooling technology delivers:
Continuous 1-hour operation at 600kV
Temperature stability within 45°C rise
IEC 60296 compliant insulating oil
Modular & Scalable Design
Removable stability pedestal with seismic rating
Special measuring lead-wire for VF sources (30-300Hz)
Supports single and two-stage serial configurations
Certifications & Safety Compliance
International Standards
IEC 60060-1/2: High-voltage test techniques
IEC 60270: Partial discharge measurements
IEEE 4: Standard for HV testing
ANSI C92.2: Capacitive voltage dividers
Safety Systems
Overvoltage automatic disconnect (660kV threshold)
Pressure-relief diaphragm for dielectric protection
Dual-point temperature monitoring
Industrial Applications
Power Transmission Systems
Precision measurement on 500kV+ transmission networks with IEEE C57.12.90 compliance
High-Power Test Labs
Extended test cycles at 600kV for transformer and breaker certification
Partial Discharge Research
Ultra-sensitive detection for GIS and cable systems with <2pC resolution
Technical FAQs
What calibration certificates are provided?
Each unit includes NIST-traceable calibration certificates for:
Dividing ratio accuracy (±0.5%)
Partial discharge sensitivity
Temperature-rise validation
Can this system measure impulse voltages?
Designed for 50Hz AC applications. For impulse testing (1.2/50μs), we recommend our LQHVF-IMP series with 1000kV BIL rating.
What is the recommended maintenance schedule?
Based on IEC 61462:
Dielectric oil testing: Annually
Full calibration: Every 2 years
Corona ring inspection: After transport