400kV ~ 600kV Range
LQHVF 520kV/3000pF Dual-Function Coupling Capacitor & Voltage Divider
Advanced configurable solution offering exceptional 20-300Hz frequency range with dual-stage operation for diverse high-voltage testing requirements.
Ultra-Wide Frequency: Broadest 20-300Hz operation at 520kV - ideal for SFRA, resonant testing, and harmonic analysis
Technical Specifications
Parameter | Single Stage | Two-Stage Serial | Test Standard |
---|---|---|---|
Rated Voltage | 260kV | 520kV | IEC 60060-1 |
Rated Capacity | 6000pF | 3000pF | IEEE 4 |
Frequency Range | 20Hz - 300Hz | IEC 60076-18 | |
Voltage Ratio Error | ≤1% (effective value) | IEC 61869-5 | |
Dielectric Loss | <0.5% | IEC 60422 | |
Measuring Accuracy | ≤1.5% | IEEE 112 | |
Dividing Ratio | 6000:1 | N/A | |
Continuous Operation | 60 minutes @ 100% rating | IEEE C57.91 | |
Insulation Withstand | 572kV (110% rated) for 60s | IEC 60071 | |
Cooling System | ONAN (Oil Natural Air Natural) | IEEE C57.12.00 |
Configurable Operation Modes
Single-Stage Operation
260kV maximum voltage
6000pF capacity
Ideal for medium-voltage equipment testing
Two-Stage Serial Operation
520kV maximum voltage
3000pF capacity
Full 20-300Hz frequency capability
Rapid Reconfiguration
Field-switchable in 15 minutes
Maintains calibration in both modes
No specialized tools required
Advanced Performance Features
Ultra-Wide Frequency Range
20-300Hz operation (15:1 ratio)
Stable performance at low frequencies
Ideal for transformer SFRA testing
Precision Ratio Accuracy
≤1% voltage ratio error
6000:1 nominal dividing ratio
High-resolution measurement
Robust Insulation System
572kV withstand capability
ONAN cooling maintains stability
<0.5% dielectric loss
Dual-Function Capabilities
Coupling Capacitor Function
3000pF capacity (serial configuration)
20-300Hz signal injection capability
Power line carrier communication
Precision Voltage Measurement
6000:1 dividing ratio
Special lead-wire to VF sources
Scalable HV connections
Simultaneous operation supported for integrated monitoring systems
Frequency Performance Validation
Frequency | Voltage Ratio Error | Measuring Accuracy |
---|---|---|
20Hz | ≤0.95% | ≤1.45% |
50/60Hz | ≤0.85% | ≤1.25% |
150Hz | ≤0.92% | ≤1.35% |
300Hz | ≤0.98% | ≤1.48% |
Tested at 520kV in two-stage configuration per IEEE 4 standards
Transport-Optimized Design
Modular Corona System
Aerospace-grade aluminum corona rings
Quick-disconnect segments
Corona-free HV connections
Removable Stability Pedestal
Engineered for seismic stability
Tool-free assembly/disassembly
Integrated measurement ports
Field-Deployment Ready
Rapid reconfiguration capability
All accessories fit in single transport case
On-site calibration maintenance
Industry Applications
Transformer SFRA Testing
Full 20-300Hz range for sweep frequency response analysis
Variable Frequency Resonant Testing
Precision measurement in resonant circuits
High-Voltage Research
Configurable stages for experimental setups
Field Commissioning
Transportable solution for on-site acceptance testing
Compliance & Certifications
IEC 60060-1: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 61869-11: Coupling capacitors
IEC 60076-18: Frequency response testing
CE, RoHS, and UKCA certified
Safety Compliance: Meets IEEE 516-2022 safety requirements for 520kV installations