High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

400kV ~ 600kV Range

LQHVF 600kV/3000pF Capacitive Voltage Divider | High-Capacity Coupling Capacitor for HV Systems

High-precision 600kV/3000pF capacitive voltage divider with 2000:1 ratio & <10pC PD. Features aluminum corona rings, removable base, and ONAN cooling for 1-hour continuous operation at 660kV.


  • US$ 13,115.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 600kV/3000pF Capacitive Voltage Divider: Advanced HV Measurement Solution

High-Capacity Precision for Critical HV Applications

Designed for demanding high-voltage environments, the LQHVF 600kV/3000pF Capacitive Voltage Divider delivers exceptional accuracy in power transmission testing, substation commissioning, and industrial HV systems. With its 2000:1 ratio and enhanced 3000pF capacity, this coupling capacitor ensures reliable measurements under extreme electrical loads.

Technical Specifications

ParameterSpecificationCompliance Standard
Rated Voltage600kV AC @ 50HzIEC 60060-1
Nominal Capacitance3000pF ±10%IEC 60137
Dividing Ratio2000:1IEEE 4
Dielectric Loss<0.2%IEC 60247
Partial Discharge (PD)<10pC @ 480kVIEC 60270
Insulation Withstand660kV (110% rated) for 1 minuteIEC 60071-2
Measuring Accuracy≤1%IEC 61869-11
Continuous Operation1 hour @ 600kVANSI C57.12.90

Innovative Design Features

Aluminum Alloy Corona Rings

Lightweight yet durable corona suppression rings enable compact packing and transportation while maintaining corona-free operation up to 660kV.

Removable Stabilizing Pedestal

Engineered base provides exceptional stability during field testing with quick-disconnect functionality for rapid deployment.

Multi-Configuration HV Measurement

Specialized lead-wire system supports:

  • Single-stage and two-stage serial voltage measurement

  • Scalable corona-free HV connections

  • Compatibility with variable frequency power sources

ONAN Cooling Technology

Oil-Natural Air-Natural cooling maintains thermal stability during extended 600kV operations, preventing dielectric degradation.

Performance Validation Testing

Rigorous quality verification includes:

  • Partial Discharge Certification: <10pC at 480kV (80% of rated voltage)

  • Dielectric Strength Test: 1-minute withstand at 660kV with zero discharge events

  • Thermal Endurance: 60-minute continuous operation at full load with <2°C oil temperature rise

Industry Applications

Power Transformer Testing

Precision ratio measurement for 500kV+ transformers

HVDC Converter Stations

Voltage monitoring in high-interference environments

GIS Partial Discharge Analysis

Detection sensitivity down to 3pC in gas-insulated systems

High-Power Laboratory Calibration

NIST-traceable reference standard

Safety Compliance & Certifications

  • Clearance distances: IEEE 1308

  • Dielectric testing: IEC 60060-2

  • Environmental protection: IP65-rated components

  • Safety certification: UL 61010-1, CSA C22.2 No. 61010-1

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message