LQHDR 50kV/5kΩ/4A Damping Resistor - Heavy-Duty HV Testing Solution

Industrial-grade 50kV damping resistor with 5kΩ resistance and 4A current capacity. Features <10pC PD level, 1-hour full load operation, and 100K max temperature rise.


  • US$ 1,137.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series: 50kV/5kΩ/4A Heavy-Duty Damping Resistor

High-Power Solution for Demanding HV Applications

Engineered for industrial-scale testing, the LQHDR 50kV/5kΩ/4A damping resistor delivers 200kW power handling in transformer testing, circuit breaker validation, and high-current impulse systems. With robust thermal management and ultra-low PD levels, it withstands extreme electrical stress in 60Hz applications.

Technical Specifications

ParameterSpecificationStandard
ModelLQHDRIEC 60270 Compliant
Rated Voltage50kV AC
Nominal Resistance5kΩ ±2%
Rated Current4A
Power Rating200kW (calculated from V×I)
Partial Discharge (PD)<10pC @ 50kV (system level)
Frequency Rating60Hz

Operational Parameters

⏱️ Duty Cycle & Thermal Performance

  • Full load operation: 60 minutes continuous @ 50kV/4A (100% UH/IH)

  • Max. surface temperature rise: ≤100K @ continuous full current

  • Cooling system: Forced-air or oil-immersion required for sustained operation

Important: Temperature rise measured per IEC 60076-14 using infrared thermography. Requires minimum 1m clearance for heat dissipation.

High-Current Applications

⚡ Power Transformer Testing

Handles inrush currents during short-circuit tests on 100MVA+ transformers. Compatible with IEC 60076 standards.

🔌 Circuit Breaker Validation

Damps arc energy during HV breaker interruption tests at 50kV/4A. Critical for ANSI C37.09 compliance.

⚡️ Impulse Current Generators

Manages 4A continuous discharge in lightning current simulation (8/20μs) per IEC 62305.

Design Features

  • Industrial cooling fins: Extruded aluminum with 200% surface area enhancement

  • Parallel resistive elements: 16-section design for current sharing

  • Corona suppression: Graded-ring terminals rated for 70kV BIL

  • Modular design: Stackable configuration for 200kV+ systems

  • Thermal monitoring: Integrated K-type thermocouple ports

Installation & Safety

  1. Maintain minimum 1m clearance from other equipment

  2. Implement forced-air cooling (≥2m³/min airflow) for >30 minute operations

  3. Verify grounding resistance

    <0.1ω 80="" per="" ieee="">
  4. Use IR thermometer to monitor surface temperature during initial tests

Warning: Never exceed 60-minute continuous operation at full load. Surface temperatures may reach 150°C - use thermal protection gear.

Maintenance Protocol

  • Monthly resistance verification (±2% tolerance)

  • Quarterly thermal imaging inspection

  • Annual dielectric test: >500MΩ @ 10kV DC

  • Re-torque terminals to 25Nm every 6 months