LQHDR 100kV/0.25A Damping Resistor - 10kΩ HV Resistor with 60-Min Operation & <5pC PD

High-efficiency 100kV/10kΩ damping resistor rated for 0.25A with <5pC partial discharge. Features 60-min full-load operation, ≤80K temperature rise, and lightweight design (<5kg). Ideal for extended HV testing.


  • US$ 1,344.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series 100kV/10kΩ/0.25A Extended-Run Damping Resistor

Engineered for long-duration high-voltage testing applications requiring stable performance and ultra-low partial discharge in a lightweight package.

Technical Specifications

ParameterSpecification
Rated Voltage100kV AC (50/60Hz)
Nominal Resistance10kΩ ±1%
Rated Current0.25A continuous
Power Rating25kW (intermittent)
Partial Discharge<5pC at 100kV
Max Temperature Rise≤80K at 100% load
Full-Load Operation60 minutes at 100kV/0.25A
Continuous OperationUnlimited at 80kV/0.2A (80% rating)
DimensionsØ70/115mm × 850mm (tapered design)
Weight<5kg
Dielectric Strength120kV/1min (IEC 60243)

Key Performance Features

  • Extended Operation: 60-min full-power capability + unlimited operation at 80% rating

  • Ultra-Lightweight: Advanced composite materials enable <5kg weight (40% lighter than conventional models)

  • Stable PD Performance: <5pC partial discharge maintained throughout operating cycle

  • Efficient Cooling: Aerodynamic fin design ensures ≤80K temperature rise without forced air

  • Low Inductance: <3μH for accurate high-frequency response

Operational Modes

Full-Power Mode

  • Voltage: 100kV

  • Current: 0.25A

  • Duration: 60 minutes max

  • Cooling: 120 min cooldown required

Continuous Mode

  • Voltage: 80kV (80%)

  • Current: 0.2A (80%)

  • Duration: Unlimited

  • Temp Rise: ≤50K

Mechanical Design

  • Tapered Profile: Ø70mm (terminals) to Ø115mm (center) for optimized electric field distribution

  • Lightweight Construction: Carbon-fiber reinforced polymer core

  • Terminals: Dual corona-free silicone connectors

  • Mounting: Integrated M10 mounting points at both ends

  • Environmental Rating: IP55 (dust/water resistant)

Application Scenarios

Extended-Duration Testing

  • Transformer temperature rise tests

  • Long-term cable aging studies

  • Dielectric absorption measurements

Field Testing

  • Mobile HV test laboratories

  • Substation commissioning

  • Renewable energy farm maintenance

Installation Guidelines

  1. Mount vertically or horizontally with minimum 40cm clearance

  2. Use HV silicone cables (min. 16mm² cross-section)

  3. Ensure ambient temperature ≤40°C for full-power operation

  4. Ground terminal resistance <0.5Ω

  5. For ceiling mounting: Use safety cable (max. 1m length)

Compliant with IEC 61010-1:2010 safety standards for HV equipment.

Thermal Performance

Operation LevelDurationTemperature Rise
100% (100kV/0.25A)60 min≤80K
90% (90kV/0.225A)120 min≤70K
80% (80kV/0.2A)Continuous≤50K

Natural convection cooling sufficient for all operating modes.

Maintenance Protocol

  • Pre-Use: Visual inspection and IR test (2.5kV DC, min. 100GΩ)

  • Monthly: Terminal cleaning with non-conductive solvent

  • Bi-Annual: Full calibration per IEC 60060-2

  • After Full-Power Use: 2-hour cooldown before storage