LQHDR 100kV/2KΩ/1.515A Damping Resistor: High-Current Precision for Power Systems
Engineered for High-Current HV Applications
The LQHDR 100kV/2KΩ/1.515A damping resistor delivers unprecedented 1.515A current capacity at 100kV in a compact form factor. Designed for demanding applications requiring high energy dissipation:
Circuit breaker testing
High-power transformer diagnostics
Generator withstand testing
HVDC converter station validation
Technical Specifications
Parameter | Value |
---|---|
Rated Voltage | 100kV |
Rated Current | 1.515A |
Peak Power Handling | 151.5kW |
Nominal Resistance | 2kΩ |
Partial Discharge | <3pC at 100kV |
Dimensions | 70/115mm × 850mm |
Weight | <5kg |
Full Load Operation | 60 minutes at 100% rating |
Continuous Operation | Unlimited at 80% rating |
Max Temperature Rise | 80K (at 100% load) |
Frequency | 50Hz |
Breakthrough Performance Features
High-Current Capability
1.515A rating at 100kV - 10× higher current density than standard resistors - enables testing of high-power equipment.
Advanced Thermal Management
Maintains ≤80K temperature rise at 151.5kW peak power through proprietary cooling technology.
Ultra-Low Inductance
Special winding technique ensures<1μh inductance="" for="" accurate="" transient="" response="" in="" fast-switching="" tests.="">
High-Power Application Solutions
Circuit Breaker Testing
Validates interruption capability at 100kV/1.515A per IEC 62271-100 standards.
Generator Stator Testing
Damps switching transients during HV withstand tests on multi-megawatt generators.
HVDC Valve Testing
Provides stable load for thyristor valve verification at 100kV DC with high current pulses.
Compact Power Design
Space-Optimized Package
850mm length and dual-diameter (70/115mm) design fits standard test bays despite 151.5kW capability.
Lightweight Construction
Advanced materials keep weight under 5kg - 70% lighter than comparable high-current resistors.
Rapid Deployment
Integrated lift points and quick-connect terminals enable setup in under 15 minutes.
Safety Engineering
Arc-Flash Protection
Self-extinguishing composite housing contains internal arcs up to 150kA.
Thermal Safeguards
Redundant temperature sensors trigger automatic shutdown at 85K rise.
Voltage Monitoring
Integrated capacitive taps enable real-time voltage verification without direct contact.
Operational Guidelines
Cooling Requirements: Minimum 0.5m clearance for airflow; ambient
<40°c<>Mounting: Vertical orientation recommended; secure base with M12 bolts
Connections: Use 120mm² minimum cable cross-section
Maintenance: Quarterly IR testing; annual full-power validation