<150kV Range
LQHDR Series: High-Current 50kV Damping Resistor for Demanding HV Applications
High-Power Damping for Industrial Test Systems
The LQHDR 50kV/5kΩ/0.2A damping resistor delivers robust performance with ultra-low partial discharge (<5pc) in="" high-current="" test="" environments.="" engineered="" for="" impulse="" generators="">
Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 50kV AC/DC | IEC 60060-1 |
Nominal Resistance | 5kΩ ±1% | IEC 60115-8 |
Rated Current | 0.2A continuous | IEC 61071 |
Power Rating | 10kW peak (during 15-min cycle) | IEC 60298 |
Partial Discharge (PD) | <5pC at 50kV | IEC 60270 |
Operating Time | 15 minutes ON at 100% load (Cooling period required) | IEEE 4-2013 |
Dimensions | Ø100 × 350mm | - |
Weight | <10kg | - |
Frequency | 48-62Hz (50Hz rated) | IEEE C57.12.90 |
Performance Advantages
High-Current Capability
Designed for 0.2A continuous current (10kW power), featuring heavy-duty terminals and low-inductance windings to minimize voltage drop during high-energy tests.
Strict PD Control
Corona-free construction maintains partial discharge below 5pC even at 50kV, critical for accurate PD measurements in HV equipment testing.
Optimized Thermal Design
Forced-air cooling fins and ceramic composite core enable efficient heat dissipation during 15-minute high-power operations. Internal temperature limited to 85°C.
Duty Cycle Operation
Operational Protocol (per IEEE 4-2013):
Operate at 100% rated voltage (50kV) and current (0.2A) for 15 minutes maximum
Cooling period: Minimum 45 minutes at zero load
Maximum 8 cycles per 24-hour period
⚠️ Critical Note: Continuous operation beyond 15 minutes may cause thermal damage. Ambient temperature must be ≤40°C.
Physical Construction
Dimensions: Ø100mm × 350mm Height
Weight: 9.5kg (including heavy-duty terminals)
Mounting: M12 terminals with 60mm creepage distance
Figure: Heavy-duty design for high-power applications
Industrial Applications
Circuit Breaker Testing: Damping switching surges in 50kV/20kA test circuits
Transformer Impulse Tests: Waveform control in IEC 60076-3 lightning impulse tests
HVDC Converter Stations: Harmonic filtering in 50kV DC systems
Research Laboratories: Load banks for high-power component validation
Field Data: Achieved 0.5% waveform accuracy in 40kA short-circuit tests.
Safety & Compliance
Dielectric Strength: 90kV/min (IEC 61010-1)
Environmental Rating: IP54 (dust and splash resistant)
Safety Standards: CAT IV 1000V
Over-Temperature Protection: Automatic cutoff at 90°C
Terminal guards included for arc-flash protection.