<150kV Range
LQHDR Series: 50kV/5kΩ/0.1A Compact Damping Resistor
Portable Solution for Field Testing Applications
Designed for mobile test teams, the LQHDR 50kV/5kΩ/0.1A damping resistor combines high-voltage performance with compact portability. With its lightweight construction (<10kg) and="" minimal="" partial="" discharge="">
Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Model | LQHDR | IEC 60270 Compliant |
Rated Voltage | 50kV AC | |
Nominal Resistance | 5kΩ ±1% | |
Rated Current | 0.1A | |
Power Rating | 5kW (calculated from V×I) | |
Partial Discharge (PD) | <5pC @ 50kV | |
Frequency Rating | 50Hz | |
Operating Time | 60 min @ 100% rated voltage/current |
Physical Dimensions & Handling
📐 Dimensions
φ100mm × 350mm (diameter × height)
⚖️ Weight
<10kg (22 lbs) - 40% lighter than standard HV resistors
🚚 Portability
Integrated carrying handles and waterproof storage case
Field Advantage: Compact size enables testing in confined spaces like switchgear cabinets and transformer bays where standard resistors can't fit.
Key Applications
🏭 Mobile Substation Testing
Ideal for dielectric tests on distribution transformers (11kV-33kV class) during field maintenance.
🔬 On-Site PD Measurement
Enables accurate partial discharge detection (<5pc) in="" cable="" termination="" tests="" without="" fixed="" lab="" equipment.="">
⚡ Field Research Projects
Portable solution for university research teams conducting HV experiments in remote locations.
Design Features
Advanced composite housing: Fiber-reinforced polymer for 50kV insulation in compact form
Integrated cooling fins: Passive thermal management for 60-min full load operation
Quick-connect terminals
Corona-free design: Triple-shielded connections with silicone insulation
Environmental protection: IP54 rating for dust/moisture resistance
Safety & Field Operation
Verify ground connection (
<0.5ω) before="" energizing="">Maintain minimum 0.5m clearance from grounded surfaces
Monitor surface temperature with IR thermometer (max 80°C)
Allow 30-minute cooldown between full-load tests
Safety Certification: Compliant with IEC 61010-1 safety requirements for portable HV equipment.
Maintenance Protocol
Monthly visual inspection for casing integrity
Quarterly resistance verification (±1% tolerance)
Annual dielectric test: >1000MΩ @ 5kV DC
Clean terminals with isopropyl alcohol after field use