LQHVF 50kV/500pF Capacitive Voltage Divider & Coupling Capacitor - Precision EHV Instrument

Ultra-precise LQHVF 50kV/500pF dual-function instrument with <0.2% dielectric loss, <10pC PD level & 1000:1 ratio. Designed for critical EHV measurements at 60Hz.


  • US$ 2,015.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 50kV/500pF Capacitive Voltage Divider & Coupling Capacitor

Industry-Leading Efficiency: Ultra-low <0.2% dielectric loss for precision measurements in 50kV systems at 60Hz

Precision Instrument for Extra-High Voltage Systems

Engineered for critical 50kV/60Hz applications, the LQHVF delivers laboratory-grade accuracy with field-deployable reliability. The optimized 500pF capacitance provides:

  • Ultra-low dielectric dissipation (<0.2%)

  • Precise voltage measurement with ≤±1% accuracy

  • Partial discharge detection within complete test systems

  • Superior thermal stability with ONAN cooling

50kV

Technical Specifications

ParameterSpecificationPerformance Advantage
Rated Voltage50kVEHV system compatibility
Frequency60HzNorth American power system standard
Capacitance500pFOptimal balance for PD coupling & measurement
Voltage Ratio1000:150V output at 50kV input
Dielectric Loss<0.2%Industry-leading insulation efficiency
Partial Discharge<10pC @ 100% UHIEC 60270 compliant system performance
Accuracy≤±1%Meets IEEE 4-2013 Class 0.5 standards
Operating Time60min @ 50kVFull-power diagnostic capability

Advanced PD Test System Performance

Complete Test System Integration

The <10pC PD specification applies to the entire measurement chain, including:

  • Coupling capacitor (this unit)

  • Measurement impedance

  • PD analyzer

  • Shielding and grounding system

Calibration Requirement: System verification per IEC 60270 using calibrated pulse injector

Innovative Structural Design

Corona Rings

Optimized geometry

Removable design

Ly Arm

Measurement interface

BNC output

Hy Arm

High-voltage terminal

50kV rated

Removable Base

Stabilized platform

Leveling feet

Oil-Immersed Construction

High-grade mineral oil with dielectric strength >60kV/mm

Benefit: Enhanced arc suppression and thermal management

Modular Design

Quick-disconnect components

Benefit: 10-minute field assembly

ONAN Cooling

Natural oil/air convection

Benefit: Stable operation at full load

Dual-Function Operation

Voltage Division

Application: RMS voltage measurement

Accuracy: ≤±1% at 60Hz

Output: 50V at 50kV input

PD Coupling

Application: Partial discharge detection

Sensitivity: <10pC system performance

Bandwidth: 30Hz-500kHz

Technical Note: The 500pF capacitance provides optimal impedance for 50kV/60Hz systems, balancing PD sensitivity and high-frequency response

Thermal Management

  • ONAN System: Oil Natural Air Natural cooling

  • Thermal Performance: <50°C rise during 60-min operation

  • Operating Protocol:

    • 60 minutes continuous at 50kV (100% UH)

    • Followed by 90-minute cooling period

  • Cooling Requirements: 30cm clearance around unit

Compliance & Applications

Standards Compliance: IEC 60270:2000 (PD), IEEE 4-2013 (Testing), ANSI C57.13 (Accuracy)

Critical Applications:

  • Factory acceptance testing of 50kV switchgear

  • On-line PD monitoring in substations

  • Dielectric loss measurement in power transformers

  • High-voltage research at 60Hz

  • Calibration of protective relays

Operational Protocol

Preparation

  1. Assemble components on stable surface

  2. Connect Ly-arm to measurement device

  3. Ground base with ≥12mm² cable

Energization

  1. Ramp voltage gradually (≤5kV/s)

  2. Monitor for 60 minutes maximum

  3. Verify oil temperature <85°C

PD Measurement

  1. Connect to PD analyzer via Ly-arm

  2. Calibrate system with pulse injector

  3. Use double-shielded coaxial cables

Shutdown

  1. De-energize system

  2. Wait 10 minutes for discharge

  3. Disassemble components

Why This Instrument?

Dielectric Precision

<0.2% loss for accurate measurements

System Integration

<10pC PD system performance

Thermal Stability

ONAN cooling for continuous operation

Frequency Optimized

Designed for 60Hz power systems