<100kV Range
LQHVF 50kV/500pF Capacitive Voltage Divider & Coupling Capacitor
Ultra-Efficient Design: Industry-leading <0.2% dielectric loss for precision measurements in 60Hz EHV systems
Precision Instrument for 60Hz Power Systems
Engineered for 50kV/60Hz applications, the LQHVF delivers laboratory-grade accuracy with field reliability. The optimized 500pF capacitance provides:
Ultra-low dielectric dissipation (<0.2%)
Complete test system PD detection (<10pC)
Precise voltage measurement with ≤±1% accuracy
Thermal stability with ONAN cooling
50kV
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 50kV | EHV system compatibility |
Frequency | 60Hz | North American power standard |
Capacitance | 500pF | Optimal balance for PD coupling & measurement |
Voltage Ratio | 1000:1 | 50V output at 50kV input |
Dielectric Loss | <0.2% | Industry-leading insulation efficiency |
Partial Discharge | <10pC @ 100% UH | Complete test system performance (IEC 60270) |
Accuracy | ≤±1% | Meets IEEE 4-2013 standards |
Operating Time | 60min @ 50kV | Full-power diagnostic capability |
Dielectric Efficiency Advantage
The <0.2% dielectric loss represents a 60% improvement over standard dividers, enabling:
More accurate power factor measurements
Reduced thermal stress during operation
Enhanced measurement sensitivity
Long-term insulation stability
Complete PD Test System Performance
System Approach: The <10pC specification applies to the entire measurement chain including coupling capacitor, measurement impedance, and PD analyzer
Calibration Requirements:
Verify system with calibrated pulse injector
Use NIST-traceable calibration sources
Perform quarterly system checks per IEC 60270
Maintain measurement cables ≤1.5m
Modular Structural Design
Corona Rings
Aluminum alloy
Removable design
Ly Arm
Measurement interface
BNC output
Hy Arm
High-voltage terminal
50kV rated
Removable Base
Stabilized platform
Leveling feet
Oil-Immersed Construction
High-grade mineral oil with dielectric strength >60kV/mm
Benefit: Enhanced thermal management and arc suppression
Quick-Disconnect System
Tool-free assembly in 10 minutes
Benefit: Rapid field deployment and maintenance
Thermal Management System
ONAN Cooling: Oil Natural Air Natural convection
Thermal Performance: <45°C rise during 60-min operation at 50kV
Operating Protocol:
60 minutes continuous at 50kV (100% UH)
Recommended 60-minute cooling period
Cooling Requirements: Maintain 25cm air clearance around unit
Compliance & Applications
Standards Compliance: IEC 60270:2000 (PD), IEEE 4-2013 (Testing), ANSI C57.13 (Accuracy)
Critical Applications:
Factory acceptance testing of 50kV switchgear
On-line PD monitoring in 60Hz substations
Dielectric loss measurement in power transformers
High-voltage research at 60Hz
Calibration of protective relays
Operational Protocol
Preparation
Assemble components on stable surface
Connect Ly-arm to measurement device
Ground base with ≥12mm² cable
Energization
Ramp voltage gradually (≤5kV/s)
Operate at 100% UH (50kV)
Max 60 minutes continuous
PD Measurement
Connect to PD analyzer via Ly-arm
Calibrate complete system
Use double-shielded coaxial cables
Shutdown
De-energize system
Wait 10 minutes for discharge
Disassemble components
Safety Note: The "100% UH, 100% IH" operating condition refers to 50kV at maximum continuous current rating
Why This Instrument?
Dielectric Efficiency
<0.2% loss for precise measurements
System Integration
<10pC PD system performance
Frequency Optimized
Designed for 60Hz power systems
Thermal Resilience
ONAN cooling maintains stability