LQHVF 50kV/500pF Capacitive Voltage Divider & Coupling Capacitor - Precision EHV Instrument

Ultra-efficient LQHVF 50kV/500pF dual-function instrument with <0.2% dielectric loss, <10pC PD system performance & 60Hz optimization. Designed for critical EHV applications.


  • US$ 2,015.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 50kV/500pF Capacitive Voltage Divider & Coupling Capacitor

Ultra-Efficient Design: Industry-leading <0.2% dielectric loss for precision measurements in 60Hz EHV systems

Precision Instrument for 60Hz Power Systems

Engineered for 50kV/60Hz applications, the LQHVF delivers laboratory-grade accuracy with field reliability. The optimized 500pF capacitance provides:

  • Ultra-low dielectric dissipation (<0.2%)

  • Complete test system PD detection (<10pC)

  • Precise voltage measurement with ≤±1% accuracy

  • Thermal stability with ONAN cooling

50kV

Technical Specifications

ParameterSpecificationPerformance Advantage
Rated Voltage50kVEHV system compatibility
Frequency60HzNorth American power standard
Capacitance500pFOptimal balance for PD coupling & measurement
Voltage Ratio1000:150V output at 50kV input
Dielectric Loss<0.2%Industry-leading insulation efficiency
Partial Discharge<10pC @ 100% UHComplete test system performance (IEC 60270)
Accuracy≤±1%Meets IEEE 4-2013 standards
Operating Time60min @ 50kVFull-power diagnostic capability

Dielectric Efficiency Advantage

The <0.2% dielectric loss represents a 60% improvement over standard dividers, enabling:

  • More accurate power factor measurements

  • Reduced thermal stress during operation

  • Enhanced measurement sensitivity

  • Long-term insulation stability

Complete PD Test System Performance

System Approach: The <10pC specification applies to the entire measurement chain including coupling capacitor, measurement impedance, and PD analyzer

Calibration Requirements:

  1. Verify system with calibrated pulse injector

  2. Use NIST-traceable calibration sources

  3. Perform quarterly system checks per IEC 60270

  4. Maintain measurement cables ≤1.5m

Modular Structural Design

Corona Rings

Aluminum alloy

Removable design

Ly Arm

Measurement interface

BNC output

Hy Arm

High-voltage terminal

50kV rated

Removable Base

Stabilized platform

Leveling feet

Oil-Immersed Construction

High-grade mineral oil with dielectric strength >60kV/mm

Benefit: Enhanced thermal management and arc suppression

Quick-Disconnect System

Tool-free assembly in 10 minutes

Benefit: Rapid field deployment and maintenance

Thermal Management System

  • ONAN Cooling: Oil Natural Air Natural convection

  • Thermal Performance: <45°C rise during 60-min operation at 50kV

  • Operating Protocol:

    • 60 minutes continuous at 50kV (100% UH)

    • Recommended 60-minute cooling period

  • Cooling Requirements: Maintain 25cm air clearance around unit

Compliance & Applications

Standards Compliance: IEC 60270:2000 (PD), IEEE 4-2013 (Testing), ANSI C57.13 (Accuracy)

Critical Applications:

  • Factory acceptance testing of 50kV switchgear

  • On-line PD monitoring in 60Hz substations

  • Dielectric loss measurement in power transformers

  • High-voltage research at 60Hz

  • Calibration of protective relays

Operational Protocol

Preparation

  1. Assemble components on stable surface

  2. Connect Ly-arm to measurement device

  3. Ground base with ≥12mm² cable

Energization

  1. Ramp voltage gradually (≤5kV/s)

  2. Operate at 100% UH (50kV)

  3. Max 60 minutes continuous

PD Measurement

  1. Connect to PD analyzer via Ly-arm

  2. Calibrate complete system

  3. Use double-shielded coaxial cables

Shutdown

  1. De-energize system

  2. Wait 10 minutes for discharge

  3. Disassemble components

Safety Note: The "100% UH, 100% IH" operating condition refers to 50kV at maximum continuous current rating

Why This Instrument?

Dielectric Efficiency

<0.2% loss for precise measurements

System Integration

<10pC PD system performance

Frequency Optimized

Designed for 60Hz power systems

Thermal Resilience

ONAN cooling maintains stability