LQHDR 50kV/10KΩ/0.14A Damping Resistor - High Voltage Testing Solution

High-performance 50kV damping resistor with 10KΩ resistance and 0.14A rating. Features <5pC partial discharge level, 60min@100% voltage operation, and IEC-compliant thermal management.


  • US$ 982.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series: 50kV/10KΩ/0.14A Precision Damping Resistor

Critical Component for High-Voltage Systems

The LQHDR damping resistor provides essential surge protection in transformer testing, switchgear diagnostics, and partial discharge measurement systems. Engineered for 50kV applications with ultra-low PD levels, it ensures signal integrity in demanding electrical environments.

Technical Specifications

ParameterSpecificationStandard
ModelLQHDRIEC 60270 Compliant
Rated Voltage50kV AC
Nominal Resistance10KΩ ±1%
Rated Current0.14A
Partial Discharge (PD)<5pC @ 50kV
Frequency Rating50Hz
Power Rating700W (calculated from V×I)

Operational Parameters

Thermal Performance

  • Full load operation: 60 minutes continuous @ 100% rated voltage

  • Sustained operation: Continuous @ 80% rated voltage/current

  • Max. temperature rise: ≤80K (resistor body) @ 100% load

System Temperature Limits

  • Transformer windings: ≤65K temperature rise

  • Oil surface: ≤55K temperature rise

Key Applications

⚡ Transformer Testing Systems

Provides precise damping for dielectric tests and PD measurements on power transformers up to 132kV class.

🔬 Partial Discharge Detection

Ensures measurement accuracy with <5pC background noise during critical HV cable and GIS testing.

🏭 Impulse Voltage Circuits

Controls wavefront timing in lightning impulse generators (1.2/50μs) per IEC 60060-1 standards.

Design Features

  • Low-inductance design: Minimizes waveform distortion at 50Hz

  • Oil-immersed construction: Mineral oil cooling for thermal stability

  • Corona-free terminals: Silicone-insulated connectors (70kV BIL)

  • Modular stacking: Series connection for voltages up to 400kV

Safety & Maintenance

  1. Perform dielectric tests annually: >1000MΩ @ 5kV DC

  2. Verify resistance tolerance (±1%) every 6 months

  3. Monitor oil quality per IEC 60296 standards

  4. Calibrate with reference divider per IEC 60060-2

Important: Always maintain proper grounding - NFPA 70E requires ground verification before HV testing.