>400kV Range
LQHDR 500kV/5kΩ/1.5A Protecting Resistor: Ultimate Defense for High Voltage Systems
Critical Component for Electrical Safety
Protecting resistors are indispensable in high-voltage test circuits, preventing equipment damage from transient overvoltages and oscillations. The LQHDR 500kV/5kΩ/1.5A model delivers exceptional performance with its 11.25kW power handling capacity and industry-leading partial discharge characteristics, making it ideal for transformer testing, impulse generators, and substation diagnostics.
Technical Specifications
Parameter | Specification | Standard |
---|---|---|
Rated Voltage | 500 kV AC | IEC 60060-1 |
Nominal Resistance | 5 kΩ ±1% | IEEE Std 62 |
Rated Current | 1.5 A | IEC 60115-8 |
Rated Power | 11.25 kW | IEC 60269 |
Frequency Range | 50/60/100/120 Hz | IEC 60038 |
Partial Discharge (100% Vrated) | <5 pC | IEC 60270 |
Partial Discharge (80% Vrated) | <3 pC | |
Operating Duration | 60 min @ 100% load | ANSI/NETA MTS-2019 |
Surface Temp Rise | <100 K after 60 min | IEC 60505 |
Breakthrough Performance Features
Advanced Partial Discharge Control
500kV performance: <5pC ensures measurement accuracy
Reduced voltage operation: <3pC at 400kV (80% rated)
Triple-shielded grading rings eliminate corona effects
High-Efficiency Power Handling
11.25kW continuous power for 60-minute operations
Aluminum nitride ceramic core for thermal stability
Forced-air cooling compatibility
Multi-Frequency Operation
Maintains precision across diverse testing regimes:
Standard power frequencies (50/60Hz)
Enhanced test ranges (100/120Hz)
±0.5% resistance tolerance across full spectrum
Design Innovations
Electrical Architecture
Non-inductive bifilar winding (NiCr alloy)
Voltage-gradient optimized shielding electrodes
SF6-compatible insulation system
Thermal Management System
Helical cooling fins increase surface area by 40%
Temperature rise limited to <100K at full load
Automatic derating above 40°C ambient
Critical Applications
Transformer Protection Systems
Induced voltage tests (IVT) at 100-120Hz
Partial discharge measurement circuits
Lightning impulse wavefront shaping
Specialized High-Voltage Testing
HVDC converter station commissioning
Gas-insulated substation (GIS) diagnostics
Cable factory acceptance testing
Operational Excellence
Installation Requirements
Minimum clearance: 4.5 meters (500kV)
Vertical mounting for convection cooling
Ambient temperature: -30°C to +45°C
Maintenance Protocol
Pre-operational IR scan (≥10 GΩ at 5kV DC)
Quarterly thermographic inspections
Annual PD performance validation
Performance Comparison
Feature | Industry Standard | LQHDR 500kV/5kΩ |
---|---|---|
Power Density | 8-9 kW | 11.25 kW |
PD at 80% Voltage | 5-10 pC | <3 pC |
Frequency Flexibility | 50/60Hz | 50-120Hz |
Why Choose This Resistor?
Industry-leading 11.25kW power capacity
Progressive PD reduction (<5pC@100% → <3pC@80%)
Full-spectrum frequency compatibility
Certified thermal rise <100K under continuous load
Conclusion
The LQHDR 500kV/5kΩ/1.5A protecting resistor redefines safety margins in high-voltage testing with its unmatched 11.25kW power handling, progressive partial discharge control, and multi-frequency precision. Its optimized thermal design and strict adherence to IEC/IEEE standards make it essential for utilities, testing laboratories, and manufacturers operating at the forefront of high-voltage technology.