400kV ~ 600kV Range
LQHVF 500kV/1500pF Dual-Function Coupling Capacitor & Voltage Divider
Advanced dual-set solution offering exceptional 30-300Hz frequency range with flexible configuration options for diverse high-voltage testing requirements.
Dual-Set Flexibility: Configurable as two 3000pF modules or single 1500pF system - ideal for adaptable testing scenarios
Technical Specifications
Parameter | Single Set | Two-Set Serial | Test Standard |
---|---|---|---|
Rated Voltage | 250kV | 500kV | IEC 60060-1 |
Rated Capacity | 3000pF | 1500pF | IEEE 4 |
Frequency Range | 30Hz - 300Hz | IEC 60076-18 | |
Voltage Ratio Error | ≤1% (effective value) | IEC 61869-5 | |
Dielectric Loss | <0.5% | IEC 60422 | |
Measuring Accuracy | ≤1.5% | IEEE 112 | |
Dividing Ratio | 2000:1 | N/A | |
Insulation Withstand | 550kV (110% rated) for 60s | IEC 60071 | |
Cooling System | ONAN (Oil Natural Air Natural) | IEEE C57.12.00 |
Dual-Set Configuration Advantages
Independent Module Operation
250kV per 3000pF module
Ideal for medium-voltage testing
Parallel deployment capability
Serial High-Voltage Operation
500kV at 1500pF capacity
Full 30-300Hz frequency range
Scalable corona-free connection
Rapid Reconfiguration
Tool-free setup changes
Unified calibration for all modes
Field-switchable in under 15 minutes
Advanced Performance Features
Wide Frequency Operation
30-300Hz range for diverse applications
Stable performance across spectrum
Ideal for resonant testing and SFRA
Precision Measurement
≤1% voltage ratio error
2000:1 nominal dividing ratio
Effective value accuracy
Robust Insulation
550kV withstand capability
Dual-set insulation coordination
ONAN cooling maintains stability
Dual-Function Capabilities
Coupling Capacitor Function
1500pF capacity (serial configuration)
Power line carrier communication
30-300Hz signal injection
Precision Voltage Measurement
2000:1 dividing ratio
Single and two-stage measurement
Special lead-wire to VF sources
Simultaneous operation supported in all configurations
Engineering Design Excellence
Transport-Optimized Corona System
Aerospace-grade aluminum corona rings
Segmented design for packing
Corona-free HV connections
Removable Stability Pedestal
Engineered for seismic stability
Quick assembly/disassembly
Integrated measurement ports
Modular Connection System
Scalable corona-free connections
Single/two-stage serial measurement
Variable frequency compatibility
Frequency Performance Validation
Frequency | Accuracy (500kV) | Dielectric Loss |
---|---|---|
30Hz | ±1.45% | 0.48% |
50/60Hz | ±1.25% | 0.42% |
150Hz | ±1.35% | 0.45% |
300Hz | ±1.48% | 0.49% |
Tested in two-set serial configuration per IEEE 4 standards
Versatile Applications
Resonant Test Systems
Full 30-300Hz range for variable frequency testing
Field Testing Operations
Modular design for transport and quick setup
Power Line Communication
Coupling capability for grid monitoring
Research & Development
Configurable setups for experimental designs
Compliance & Certifications
IEC 60060-1: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 61869-11: Coupling capacitors
IEC 60076-18: Frequency response testing
CE, RoHS, and UKCA certified
Safety Compliance: Meets IEEE 516-2022 safety requirements for 500kV installations