400kV ~ 600kV Range
LQHVF 500kV/10,000pF Dual-Function Coupling Capacitor & Voltage Divider
Industrial-scale solution delivering both power line communication coupling and precision voltage measurement with massive 10,000pF capacity for high-energy applications.
Record Capacity: Industry's highest 10,000pF dual-function solution at 500kV - ideal for utility-scale power systems
Technical Specifications
Parameter | Two-Stage Serial | Single Stage | Test Standard |
---|---|---|---|
Rated Voltage | 500kV | 250kV | IEC 60060-1 |
Rated Capacity | 10,000pF | 20,000pF | IEEE 4 |
Operation Frequency | 60Hz | IEC 60076 | |
Partial Discharge | ≤5pC @ 100% rated voltage | IEC 60270 | |
Dielectric Loss | <0.2% | IEC 60422 | |
Measuring Accuracy | ≤±1% | IEEE 112 | |
Dividing Ratio | 2000:1 | N/A | |
Continuous Operation | 60 minutes @ 100% rating | IEEE C57.91 | |
Insulation Withstand | 550kV (110% rated) for 1min | IEC 60071 | |
Energy Storage | 1.25 kJ | 0.625 kJ | N/A |
Cooling System | ONAN (Oil Natural Air Natural) | IEEE C57.12.00 |
Massive Capacity Performance
Unmatched Energy Handling
10,000pF capacity in serial configuration
20,000pF in single-stage operation
1.25 kJ energy storage at 500kV
Precision Measurement
±1% voltage accuracy
2000:1 nominal dividing ratio
Stable 60Hz operation
Robust Insulation
550kV withstand capability
≤5pC partial discharge at full load
Advanced dielectric fluid formulation
Dual-Function Capabilities
High-Capacity Coupling
10,000pF capacity for power line carrier
60Hz optimized signal injection
Grid-scale communication capability
Precision Voltage Measurement
2000:1 nominal dividing ratio
Single and two-stage measurement
Scalable HV connections
Energy Storage Advantage
1.25 kJ storage at 500kV
Stabilizes during transient conditions
Enhances measurement accuracy
Industrial Design Features
Optimized Corona Control
Aerospace-grade aluminum corona rings
Segmented design for transportation
Corona-free HV connections
Heavy-Duty Stability System
Engineered removable pedestal
Seismic-rated stability
Integrated measurement ports
Advanced ONAN Cooling
Natural oil-air convection
Maintains <0.2% dielectric loss
60-minute continuous operation
Performance Validation
Test Parameter | Result | Industry Benchmark |
---|---|---|
Partial Discharge @ 500kV | ≤5pC | 10-15pC (typical) |
550kV Withstand | No discharge | 110% rated standard |
Capacity Accuracy | ±2% | ±5% (typical) |
Thermal Stability | ΔT = 18°C @ full load | 25-30°C (typical) |
Testing conducted per IEC 60270 and IEEE 4 standards
Utility-Scale Applications
Extra-High Voltage Transmission
Communication coupling for 500kV+ transmission lines
Power Plant Monitoring
Integrated voltage measurement at generator outputs
Substation Automation
Dual-function operation for smart substations
Industrial Capacitor Banks
Validation testing for large compensation systems
Compliance & Certifications
IEC 60060-1: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 61869-11: Coupling capacitors
ANSI/NETA ATS-2021: Acceptance testing
CE, RoHS, and UKCA certified
Safety Compliance: Meets IEEE 516-2022 safety requirements for 500kV installations