400kV ~ 600kV Range
LQHVF 460kV/1500pF Dual-Stage Capacitive Voltage Divider
Advanced dual-stage solution offering exceptional flexibility with 20-300Hz frequency range and configurable operation modes for diverse high-voltage testing requirements.
Frequency Flexibility: Only 460kV divider supporting 20-300Hz operation - ideal for resonant testing and harmonic analysis
Technical Specifications
Parameter | Single Stage | Two-Stage Series | Test Standard |
---|---|---|---|
Rated Voltage | 230kV | 460kV | IEC 60060-1 |
Rated Capacity | 3000pF | 1500pF | IEEE 4 |
Frequency Range | 20Hz - 300Hz | IEC 60076 | |
Partial Discharge | ≤10pC @ 100% rated voltage | IEC 60270 | |
Dielectric Loss | <0.5% | IEC 60422 | |
Measuring Accuracy | ≤±1% | IEEE 112 | |
Dividing Ratio | 1000:1 | N/A | |
Continuous Operation | 60 minutes @ 100% rating | IEEE C57.91 | |
Insulation Withstand | 506kV (110% rated) for 1min | IEC 60071 | |
Cooling System | ONAN (Oil Natural Air Natural) | IEEE C57.12.00 |
Dual-Stage Operation Modes
Single-Stage Configuration
230kV maximum voltage
3000pF capacity
Ideal for medium-voltage testing
Two-Stage Series Configuration
460kV maximum voltage
1500pF capacity
Full 20-300Hz frequency range
Flexible Switching
Rapid reconfiguration capability
No tools required for mode change
Unified calibration for both modes
Advanced Performance Features
Wide Frequency Operation
20-300Hz range for diverse applications
Stable performance across entire spectrum
Ideal for harmonic analysis and resonant testing
Precision Measurement
±1% voltage accuracy
1000:1 nominal dividing ratio
Consistent across both operation modes
Robust Insulation System
506kV withstand capability (110% rated)
Zero abnormal discharge during testing
Advanced dielectric fluid formulation
Modular Design Advantages
Transport-Optimized Corona System
Aerospace-grade aluminum corona rings
Segmented design for compact packing
Corona-free HV connections
Removable Stability Pedestal
Engineered for seismic stability
Tool-free assembly/disassembly
Integrated measurement ports
Flexible Measurement System
Special lead-wire to VF power sources
Single/two-stage serial measurement
Scalable corona-free connections
Frequency Performance Validation
Frequency | Accuracy Deviation | Dielectric Loss |
---|---|---|
20Hz | +0.9% | 0.48% |
50/60Hz | +0.7% | 0.42% |
150Hz | +0.8% | 0.45% |
300Hz | +0.95% | 0.49% |
Tested at 460kV in two-stage configuration per IEEE 4 standards
Industry Applications
Resonant Test Systems
Full 20-300Hz range for variable frequency resonant testing
Transformer Frequency Response
Sweep frequency response analysis (SFRA) up to 300Hz
High-Power Harmonic Analysis
Measure harmonic distortion in HV systems
Research & Development
Flexible configuration for experimental setups
Compliance & Certifications
IEC 60060-1: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 60076-18: Frequency response testing
CE, RoHS, and UKCA certified
Safety Compliance: Meets IEEE 516-2022 safety requirements for 460kV installations