400kV ~ 600kV Range
LQHVF 450kV/12,000pF Dual-Function Coupling Capacitor & Voltage Divider
Industrial-scale dual-purpose solution delivering both power line communication coupling and precision voltage measurement with industry-leading ≤2pC partial discharge performance.
Record Capacity: Highest 12,000pF dual-function solution at 450kV - ideal for utility-scale power systems
Technical Specifications
Parameter | Specification | Test Standard |
---|---|---|
Rated Voltage | 450kV | IEC 60060-1 |
Rated Capacity | 12,000pF | IEEE 4 |
Operation Frequency | 60Hz | IEC 60076 |
Partial Discharge | ≤2pC @ 100% rated voltage | IEC 60270 |
Dielectric Loss | <0.3% | IEC 60422 |
Measuring Accuracy | ≤±1% | IEEE 112 |
Dividing Ratio | 1000:1 | N/A |
Continuous Operation | 60 minutes @ 100% rating | IEEE C57.91 |
Insulation Withstand | 495kV (110% rated) for 1min | IEC 60071 |
Cooling System | ONAN (Oil Natural Air Natural) | IEEE C57.12.00 |
Configuration | Two capacitors in series | IEC 60158 |
Energy Storage | 1.22 kJ @ 450kV | N/A |
Dual-Function Capabilities
High-Capacity Coupling
12,000pF capacity for power line carrier communication
60Hz optimized signal injection
Simultaneous PD monitoring
Precision Voltage Measurement
1000:1 nominal dividing ratio
≤±1% measurement accuracy
Single and two-stage serial measurement
Integrated System Advantage
Space-saving dual-function solution
50% reduction in installation footprint
Unified calibration for both functions
Industrial Performance Features
Ultra-Low Partial Discharge
≤2pC at 450kV (100% rated voltage)
Detects microscopic insulation defects
Industry-leading sensitivity
Massive Energy Handling
12,000pF capacity - 8x standard units
1.22 kJ energy storage capability
Ideal for high-power systems
Robust Insulation System
495kV withstand capability
Dual-capacitor series design
Zero abnormal discharge during testing
Heavy-Duty Design
Industrial Corona Management
Aerospace-grade aluminum corona rings
Segmented design for transportation
Corona-free HV connections
Reinforced Stability Pedestal
Engineered for seismic stability
Integrated measurement ports
Tool-free assembly/disassembly |
Advanced ONAN Cooling
Optimized for high-capacity operation
Maintains <0.3% dielectric loss
Natural convection thermal management
Performance Validation
Test Parameter | Result | Industry Benchmark |
---|---|---|
Partial Discharge @ 450kV | ≤2pC | 5-10pC (typical) |
495kV Withstand | No discharge | 110% rated standard |
Continuous Operation | 60 minutes stable | 30-45 min (typical) |
Energy Storage Capacity | 1.22 kJ | 0.15 kJ (typical) |
Testing conducted per IEC 60270 and IEEE 4 standards
Utility-Scale Applications
Extra-High Voltage Transmission
Communication coupling for 400kV+ transmission lines
Substation Monitoring
Integrated voltage measurement and communication
Power Plant Systems
High-capacity measurement for generator outputs
Grid Modernization
Dual-function solution for smart grid implementation
Compliance & Certifications
IEC 60060-1: High-voltage test techniques
IEEE 4: Standard for HV testing
IEC 60270: Partial discharge measurements
IEC 61869-11: Coupling capacitors
IEC 60158: Capacitor voltage transformers
ANSI/NETA ATS-2021: Acceptance testing
CE, RoHS, and UKCA certified
Safety Compliance: Meets IEEE 516-2022 safety requirements for 450kV installations