LQHVF 450kV/1000pF Dual-Function HV Solution | ≤2pC PD & ±1% Accuracy

Premium 450kV coupling capacitor & voltage divider with ≤2pC partial discharge, ±1% accuracy, 495kV withstand & 60-min continuous operation. ONAN cooling system.


  • US$ 9,967.00
  • Lead time: 30days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 450kV/1000pF Dual-Function Coupling Capacitor & Voltage Divider

Premium integrated solution delivering both power line coupling and precision voltage measurement with industry-leading ≤2pC partial discharge performance.

Dual-Function Excellence: Only 450kV solution combining communication coupling and measurement with ≤2pC PD at full load

Technical Specifications

ParameterSpecificationTest Standard
Rated Voltage450kVIEC 60060-1
Rated Capacity1000pFIEEE 4
Operation Frequency50HzIEC 60076
Partial Discharge≤2pC @ 100% rated voltageIEC 60270
Dielectric Loss<0.2%IEC 60422
Measuring Accuracy≤±1%IEEE 112
Dividing Ratio1000:1N/A
Continuous Operation60 minutes @ 100% ratingIEEE C57.91
Insulation Withstand495kV (110% rated) for 1minIEC 60071
Cooling SystemONAN (Oil Natural Air Natural)IEEE C57.12.00
ConfigurationTwo capacitors in seriesIEC 60158

Dual-Function Capabilities

Coupling Capacitor Function

  • 1000pF capacity for power line carrier communication

  • 50Hz optimized signal injection

  • PD monitoring during operation

Precision Voltage Measurement

  • 1000:1 nominal dividing ratio

  • ≤±1% measurement accuracy

  • Single and two-stage serial measurement

Integrated Design Advantage

  • Space-saving dual-function solution

  • 40% reduction in installation footprint

  • Unified calibration for both functions

Breakthrough Performance Features

Ultra-Low Partial Discharge

  • ≤2pC at 450kV (100% rated voltage)

  • Detects microscopic insulation defects

  • Industry-leading sensitivity

Robust Insulation System

  • 495kV withstand capability (110% rated)

  • Zero abnormal discharge during testing

  • Dual-capacitor series design

Extended Operation

  • 60-minute continuous operation at 450kV

  • ONAN cooling maintains thermal stability

  • Ideal for long-duration acceptance tests

Modular Design Advantages

Transport-Optimized Corona System

  • Aerospace-grade aluminum corona rings

  • Segmented design for compact packing

  • Corona-free HV connections

Removable Stability Pedestal

  • Engineered for seismic stability

  • Tool-free assembly/disassembly

  • Integrated measurement ports

Flexible Measurement System

  • Special lead-wire to VF power sources

  • Single/two-stage serial measurement

  • Scalable corona-free connections

Performance Validation

Test ParameterRequirementResult
Partial Discharge @ 450kV≤5pC≤2pC
495kV Withstand TestNo dischargePassed (0 discharges)
Continuous Operation60 minutesStable ±0.85% accuracy
Dielectric Loss @ 20°C<0.2%0.16% average

Testing conducted per IEC 60270 and IEEE 4 standards

Industry Applications

Substation Communication

Power line carrier communication with integrated voltage monitoring

Transformer Monitoring

Simultaneous coupling and PD measurement during operation

Grid Analytics

Real-time voltage measurement with communication capabilities

Smart Grid Implementation

Dual-function solution for advanced grid monitoring systems

Compliance & Certifications

  • IEC 60060-1: High-voltage test techniques

  • IEEE 4: Standard for HV testing

  • IEC 60270: Partial discharge measurements

  • IEC 61869-11: Coupling capacitors

  • IEC 60158: Capacitor voltage transformers

  • CE, RoHS, and UKCA certified

Safety Compliance: Meets IEEE 516-2022 safety requirements for 450kV installations