<100kV Range
LQHVF 30kV/300pF Capacitive Voltage Divider & Coupling Capacitor
Industry-Leading PD Performance: <3pC at 30kV - Highest sensitivity for critical insulation diagnostics
Ultra-Precise HV Instrument for Demanding Applications
Engineered for 30kV power systems, the LQHVF combines laboratory-grade accuracy with field-deployable reliability. The optimized 300pF capacitance delivers:
Ultra-sensitive partial discharge detection (<3pC)
Precise voltage measurement with ≤±1% accuracy
Extended frequency response (DC to 100kHz)
Dielectric loss monitoring in transformers and cables
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 30kV | Industrial HV system compatibility |
Capacitance | 300pF | Optimal balance for measurement & PD coupling |
Voltage Ratio | 1000:1 | Direct interface with standard instruments |
Partial Discharge | <3pC @ 30kV | Exceeds IEC 60270 Class I requirements |
Dielectric Loss | <0.5% | Superior insulation efficiency |
Accuracy | ≤±1% | Meets IEEE 4-2013 Class 0.5 standards |
Operating Time | 60min @ 30kV | Full-power diagnostic capability |
Cooling System | ONAN | Natural oil/air convection for thermal stability |
Innovative Modular Design
Corona Rings
Aluminum alloy
Removable design
HV Arm
30kV rated
Quick-disconnect
V Arm
Measurement interface
BNC output
Removable Base
Stabilized platform
Leveling feet
Oil-Immersed Construction
High-grade mineral oil enhances thermal management and arc suppression
Dielectric Strength: 45kV/mm
Quick-Disconnect System
Field assembly in under 8 minutes without special tools
Maintenance Advantage: Component-level servicing
Corona-Free Design
Optimized geometry prevents RF interference above 20kV
Measurement Integrity: Stable readings
Dual-Function Capabilities
Technical Advantage: The V-arm design provides 25% better phase accuracy than conventional L-arms for power factor measurements
Operational Modes:
Voltage Division Mode
Connection: V-arm to voltmeter
Output: 30V at 30kV input (1000:1)
Accuracy: ≤±1% from 10Hz to 10kHz
PD Coupling Mode
Connection: HV terminal to PD analyzer
Sensitivity: <3pC detection
Bandwidth: 20Hz-100kHz
Thermal Management System
ONAN Cooling: Oil Natural Air Natural convection maintains safe operating temperatures
Thermal Performance: <40°C rise during 60-min full-load operation
Cooling Requirements: Maintain 25cm clearance around unit
Operating Cycle: 60 minutes at 30kV followed by 60-minute cooling period
Compliance & Applications
Standards Compliance: IEC 60270:2000, IEEE 4-2013, EN 61869-11:2023
Critical Applications:
Partial discharge monitoring in 30kV switchgear and GIS
Factory acceptance testing of high-voltage transformers
Power quality analysis in industrial facilities
Dielectric response testing of insulation materials
Calibration of protective relays and metering systems
Operational Protocol
Assembly: Connect components (base → V-arm → HV-arm → corona rings)
Grounding: Establish earth connection with ≥12mm² cable
Cooling Check: Verify oil level via sight glass
Energization: Ramp voltage gradually to operational level
Operation:
Max 60 minutes continuous at 30kV
Follow with 60-minute cooling period
PD Measurement: Use 50Ω coaxial cable ≤1.5m to analyzer
Safety Feature: Integrated discharge resistors (800kΩ) automatically de-energize within 2 minutes
Why This Instrument Stands Out
Unmatched PD Sensitivity
<3pC detection at 30kV for early fault detection
Modular Flexibility
Removable components for easy maintenance and transport
Thermal Resilience
ONAN cooling ensures stable performance under load
Measurement Versatility