<150kV Range
LQHDR Series: Precision 30kV Damping Resistor for High-Voltage Applications
Engineered for Critical HV Systems
The LQHDR 30kV/10kΩ damping resistor delivers exceptional performance in impulse voltage testing, PD measurement, and transformer diagnostics. Designed to suppress oscillations in high-voltage circuits, this industrial-grade component ensures accurate measurements while protecting sensitive equipment from transient surges.
Technical Specifications
Parameter | Value | Standard |
---|---|---|
Rated Voltage | 30kV AC/DC | IEC 60060-1 |
Nominal Resistance | 10kΩ ±1% | IEC 60115 |
Rated Current | 0.5A continuous | IEC 61071 |
Partial Discharge (PD) | <3pC at 30kV | IEC 60270 |
Temperature Rise | ΔT ≤ 80K at full load | IEC 60076 |
Operating Time | 60 mins at 100% rating | - |
Frequency Range | 48-62Hz (50Hz rated) | IEEE C57.12.91 |
Key Performance Features
Ultra-Low Partial Discharge
With PD levels maintained below 3pC at rated voltage, the LQHDR minimizes measurement interference in precision test environments, ensuring reliable compliance with IEC 60270 requirements.
Thermal Stability
Engineered with non-inductive winding and ceramic core technology to limit temperature rise to 80K maximum during continuous 60-minute operation at 30kV/0.5A.
High-Energy Dissipation
Specialized oxide coating withstands 180J/mm³ energy density, preventing hotspots during lightning impulse tests (1.2/50μs waveforms per IEC 60060).
Industrial Applications
Impulse Voltage Generators: Waveform shaping in 0.1-100kA test systems
Partial Discharge Detectors: Reference impedance for calibrating PD measurement circuits
Transformer Testing: Damping switching surges in IEC 60076-3 tests
HVDC Systems: Harmonic suppression in converter stations
Case Example: Reduced oscillation amplitude by 92% in 400kV GIS commissioning tests.
Safety & Compliance
Designed for operation in CAT IV 600V environments with dual-isolation terminals. Meets critical standards:
Dielectric Strength: 75kV/min (IEC 61010-1)
Environmental Rating: IP54 (dust/moisture resistant)
Flame Resistance: UL94 V-0 certified housing
Configuration Notes
Mount vertically with ≥150mm clearance to grounded surfaces
Use corona rings above 25kV applications
Annual recalibration recommended per ISO 17025
Warning: Do not exceed 60-minute continuous operation at full rating.