LQHDR 20kV/5kΩ/1A Protecting Resistor | 5kW High-Voltage Power Resistor

Industrial-grade LQHDR protecting resistor: 20kV/1A capacity, 5kΩ resistance, 5kW power rating. Features cyclic 1-hour operation, ≤80K temperature rise, and nickel-chromium winding on epoxy pipe.


  • US$ 984.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series 20kV/5kΩ/1A High-Power Protecting Resistor

Robust Protection for High-Voltage Systems

The LQHDR protecting resistor delivers 5kW power handling at 20kV/1A with industrial-grade durability. Featuring nickel-chromium wire wound on an epoxy pipe and ≤80K temperature rise, it provides critical protection for:

  • Transformer divider circuits

  • High-voltage test equipment

  • Power transmission monitoring systems

  • Impulse voltage generators

Technical Specifications

ParameterSpecificationStandard
ModelLQHDR-
Rated Voltage20 kV AC/DCIEC 60137
Nominal Resistance5 kΩ ±2%IEC 60255
Rated Current1 A continuousIEC 60076
Power Rating5 kWIEC 60076-14
Partial Discharge (PD)Meets system test standardsIEC 60270
Operating Cycle1 hour ON / 1 hour OFF (4 cycles/day)IEC 60076-14
Temperature Rise≤80K at full loadIEC 60076-2
DimensionsØ150 × 450mm-
Weight<30 kg-
TerminalsFlange connections (M16)IEC 61238-1

Robust Construction

Epoxy Pipe Core Design

Nickel-chromium resistance wire precision-wound on high-grade epoxy pipe provides:

  • Dielectric strength >30kV/mm

  • Thermal stability up to 200°C

  • Mechanical vibration resistance

⌀150mm

450mm

Divider Connection System

Integrated connecting tubes enable direct mounting to transformer dividers with:

  • HV bushing compatibility

  • Thermal expansion compensation

  • Corrosion-resistant flanges

Cyclic Operation Capability

Industrial Duty Cycle

Designed for 4 daily cycles of 1-hour full-power operation (20kV/1A) followed by 1-hour cooldown period.

Thermal Management

Optimized airflow design maintains surface temperature rise ≤80K during continuous operation at 100% load:

  • Axial cooling fins

  • 6m/s natural convection rating

  • Thermal cut-off at 150°C

Industrial Applications

Transformer Divider Protection

Prevents voltage transients in measurement dividers during:

  • Lightning impulse tests

  • Switching surge measurements

  • DC withstand voltage tests

HV Test Equipment

Provides current limiting and damping in:

  • Cable fault locators

  • Circuit breaker test sets

  • Insulation resistance testers

Installation Requirements

  • Mounting: Horizontal position with 300mm clearance

  • Connections: 35mm² cables with M16 compression lugs

  • Environment: Indoor (IP54) or outdoor with canopy

  • Safety: Grounding strap connection mandatory