<100kV Range
LQHVF 18kV/3000pF Coupling Capacitor & Capacitive Voltage Divider
Dual-Function Design: Precision voltage division and PD coupling for comprehensive 18kV system diagnostics
High-Voltage Measurement Solution for Industrial Power Systems
Engineered for 18kV applications, the LQHVF combines exceptional accuracy (≤1%) with ultra-low dielectric loss (<0.2%). Its 3000pF capacitance and 1000:1 ratio enable:
Precise RMS voltage measurement in switchgear and transformers
Sensitive partial discharge detection (<5pC)
Harmonic analysis up to 15kHz bandwidth
Dielectric loss monitoring in critical HV equipment
Technical Specifications
Parameter | Specification | Performance Advantage |
---|---|---|
Rated Voltage | 18kV | Industrial power system compatibility |
Capacitance | 3000pF | Optimal signal coupling for PD detection |
Voltage Ratio | 1000:1 | Direct interface with standard instruments |
Dielectric Loss | <0.2% | Industry-leading insulation efficiency |
Partial Discharge | <5pC @ 18kV | Exceeds IEC 60270 Class I requirements |
Insulation Test | 110% rated voltage for 1min | Enhanced safety margin |
Operating Time | 60min @ 18kV | Full-power diagnostic capability |
Innovative Connection System
Single-Stage Measurement
Configuration: Direct connection via corona-free terminal
Use Case: Standard voltage monitoring
Setup Time: <5 minutes
Two-Stage Series Connection
Configuration: Cascaded HV arms
Use Case: Extended voltage range applications
Voltage Capacity: +40%
HV Connection: Corona-free terminals with scalable interfaces prevent RF interference during measurements.
Transport-Optimized Structural Design
Removable Aluminum Corona Rings: 30% smaller packaging volume for logistics efficiency
Aluminum Alloy Construction: High strength-to-weight ratio (total weight <15kg)
Modular Components: Quick-disconnect L-arm, HV arm, and base
Stabilized Pedestal: Non-slip base with leveling feet for uneven surfaces
ONAN Cooling: Oil Natural Air Natural system maintains thermal stability
Advanced Safety Features
Over-Voltage Withstand: 19.8kV (110% rated voltage) for 1 minute without discharge
Dual-Isolation Measurement: Special lead-wire connects to variable frequency power source
Automatic Discharge: Integrated bleeder resistors (500kΩ)
Visual Indicators: Oil level sight glass and pressure relief flag
Compliance & Applications
Standards Compliance:
IEC 60270:2000 (Partial Discharge Measurements)
IEEE 4-2013 (High-Voltage Testing Techniques)
EN 60060-1:2010 (HV Test Requirements)
Key Applications:
Factory acceptance testing of 18kV switchgear
On-line PD monitoring in industrial substations
Dielectric response analysis of power transformers
High-voltage research and development labs
Operational Protocol
Measurement Tip: For series connection, synchronize measurement devices using IRIG-B timecode
Grounding: Establish earth connection before energization (min 10mm² cable)
Cooling Check: Verify 20cm air clearance around unit
HV Connection: Use corona-free terminals with silicone-insulated connectors
Lead-Wire Connection: Connect measuring lead to variable frequency source
Post-Operation: Wait 5 minutes before disconnecting for capacitor discharge