High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

<100kV Range

LQHVF 10kV/3000pF Capacitive Voltage Divider & Coupling Capacitor - Dual-Purpose HV Instrument

High-capacitance LQHVF 10kV/3000pF capacitive divider with dual connectors for voltmeters & PD testers. Features <5pC discharge, ≤1% accuracy & ONAN cooling.


  • US$ 1,163.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHVF 10kV/3000pF Capacitive Voltage Divider & Coupling Capacitor

Dual-Connector Design: Simultaneous voltage measurement and partial discharge detection for comprehensive HV diagnostics

High-Capacitance Solution for Critical HV Systems

Engineered for 10kV power networks, the LQHVF 3000pF capacitive divider combines precision voltage division with PD coupling capabilities. Its high capacitance enables:

  • Accurate RMS voltage measurement via 1000:1 ratio

  • Low-impedance coupling for sensitive partial discharge detection

  • Harmonic analysis up to 10kHz bandwidth

  • Dielectric loss monitoring in transformers and cables

Technical Specifications

ParameterSpecificationOperational Advantage
Rated Voltage10kVIndustrial HV system compatibility
Capacitance3000pFEnhanced signal coupling for PD detection
Voltage Ratio1000:1Direct interface with standard voltmeters
Partial Discharge<5pC @ 10kVMeets IEC 60270 Class I requirements
Dielectric Loss<0.5%Superior insulation integrity
Temp. Coefficient<0.0005Stable readings across -20°C to +50°C
Cooling SystemONANNatural oil/air cooling for continuous operation

Dual-Output Connector System

HV Measurement Port

Function: 1000:1 reduced voltage output

Connection: Shielded coaxial to voltmeter

Accuracy: ≤±1% at 50Hz

PD Test Port

Function: Direct capacitive coupling

Connection: BNC to PD analyzer

Bandwidth: 20Hz-10kHz

Note: Simultaneous operation allows correlation of voltage transients with PD events.

Advanced Thermal Management

ONAN Cooling System: 40% longer continuous operation vs. air-cooled dividers

  • Oil-Immersed Design: Mineral oil dissipates hotspot temperatures

  • Thermal Stability: <5°C temperature rise during 60-min full-load operation

  • Operating Regimes:

    • 60 minutes at 10kV

    • Continuous duty at 8kV

Structural Features

  • Modular Construction: Removable corona rings, L-arm, HV arm, and base

  • Corona Suppression: Optimized ring geometry reduces RF interference

  • Compact Footprint: 65mm × 90mm × 420mm (fits switchgear compartments)

  • Sealed Oil System: Hermetic design prevents moisture ingress

Compliance & Applications

Standards Compliance:

  • IEC 61869-11:2023 (Instrument Transformers)

  • IEEE 4-2013 (High-Voltage Testing)

  • EN 60076-11 (Dry-Type Transformers)

Key Applications:

  1. On-line PD monitoring in substations

  2. Factory acceptance testing of HV equipment

  3. Power quality measurement in renewable energy systems

  4. Research labs studying insulation aging

Operational Protocol

  1. Grounding: Connect base to earth ground with 10mm² cable

  2. Pre-Energization Check: Verify oil level in sight glass

  3. PD Testing: Use 50Ω coaxial cable ≤3m to PD analyzer

  4. Cooling: Maintain 30cm clearance around unit

Pro Tip: For PD measurements, connect voltmeter port to oscilloscope to synchronize voltage phase with PD pulses

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message