High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

<150kV Range

LQHDR 10kV/10KΩ/0.1A Damping Resistor | High-Voltage PD Suppression Solution

LQHDR series 10kV/10kΩ damping resistor with <5pC partial discharge level. Rated for 0.1A/50Hz operations, 60min continuous duty cycle, and 80K max temperature rise. Compliant with IEC 60270 standards.


  • US$ 517.00
  • Lead time: 30 days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR Series Damping Resistor: 10kV/10kΩ High-Voltage PD Suppression

Engineered for Critical High-Voltage Applications

The LQHDR damping resistor delivers precision partial discharge (PD) suppression in high-voltage systems. With certified <5pC PD level at rated voltage and robust 10kV/0.1A capacity, it prevents voltage oscillations in:

  • Impulse voltage generators

  • HV test equipment circuits

  • Power transformer diagnostic systems

  • Partial discharge measurement setups

Key Technical Specifications

ParameterSpecificationStandard
ModelLQHDR-
Rated Voltage10 kV AC/DCIEC 60137
Nominal Resistance10 kΩ ±1%IEC 60255
Rated Current0.1 AIEC 60076
Frequency50/60 HzIEC 60255
Partial Discharge (PD)<5 pC at rated voltageIEC 60270
Operating Duration60 min continuous @ 100% loadIEC 60076-14
Temperature Rise≤80K @ full loadIEC 60076-2

Performance Advantages

Ultra-Low PD Design

Specialized resistive material maintains <5pC partial discharge at 10kV - critical for sensitive PD measurement systems requiring minimal background noise.

Robust Thermal Management

Alumina-ceramic core with nickel-chromium alloy windings ensures maximum temperature rise of 80K at full load during 60-minute operations.

Damping Efficiency

10kΩ resistance with ±1% tolerance provides precise wavefront control in:

  • Lightning impulse circuits (1.2/50μs)

  • Switching surge tests (250/2500μs)

  • DC ripple suppression

Compliance & Safety

Designed to meet international standards for HV components:

  • IEC 60270: Partial discharge measurements

  • IEC 60076-14: Power transformer applications

  • IEC 60137: Bushings for alternating voltages

  • Dielectric strength: 30kV/min (tested)

Application Notes

Installation

Mount vertically with minimum 25mm clearance to grounded surfaces. Use corona rings above 8kV applications.

Maintenance

Annual insulation resistance test: ≥1000MΩ @ 5kV DC (per IEC 60480)