High Voltage Test Solutions
Persistently developing technology, improving quality, management, and service standards

>400kV Range

LQHDR 1000kV/10kΩ0.2A Damping Resistor: Compact Design for High-Voltage Applications

Technical specifications for the LQHDR 1000kV/10kΩ/0.2A damping resistor featuring ≤5pC partial discharge, compact design (<220kg), and 60-minute continuous operation.


  • Negotiated Price
  • Lead time: 60days

>>>WhatsApp Communication<<<

Product Details

Product Tags

LQHDR 1000kV/10kΩ/0.2A Compact Damping Resistor

Electrical Specifications

ParameterSpecificationStandard
Rated Voltage1000kV ACIEC 60273
Nominal Resistance10kΩ ±0.5%IEEE 4-2013
Rated Current0.2A continuousIEC 60076
Power Rating0.4kWThermal Class A
Frequency50HzIEC 60060-1

Partial Discharge Performance

  • ≤5pC at 100% rated voltage (1000kV)

  • ≤3pC at 80% rated voltage (800kV)

  • Tested per IEC 60270 with shielded measurement

Mechanical Design & Dimensions

  • Configuration: Tapered cylindrical design

  • Base Diameter: Ø350mm

  • Top Diameter: Ø1050mm

  • Height: 3600mm

  • Total Weight: <220kg

  • Mounting: Flange base with M20 anchor points

The optimized geometry provides superior voltage distribution while minimizing footprint.

Operational Endurance

Continuous Operation: 60 minutes at:

  • 100% rated voltage (1000kV)

  • 100% rated current (0.2A)

  • Full power dissipation (0.4kW)

Lightweight Construction Features

  • Core Material: Carbon composite resistive elements

  • Structural Frame: Aerospace-grade aluminum alloy

  • Insulation System: Silicone-embedded fiberglass

  • Corona Protection: Graded ring electrodes

Space-Constrained Applications

  • Mobile high-voltage test laboratories

  • Compact substation diagnostic systems

  • On-site transformer testing units

  • University research facilities

  • Modular impulse voltage generators

Installation Advantages

  • Requires only 1.2m² floor space

  • Vertical installation with ceiling clearance ≥500mm

  • Single-person handling with lift points

  • Integrated leveling feet for uneven surfaces

Safety & Maintenance

  1. Pre-installation insulation test (min 100GΩ at 5kV DC)

  2. Quarterly visual inspection of corona rings

  3. Annual resistance calibration (±0.25% accuracy)

  4. 5-year dielectric strength verification

Compliance Standards

  • IEC 60273: High-voltage resistors

  • IEEE 4-2013: HV testing standards

  • EN 61462: Composite hollow insulators

  • IEC 62217: Polymeric HV insulators

>>>WhatsApp Communication<<<

>>>Click To Get Quote<<<

Leave Your Message

Leave Your Message